Designed for demanding mobile environments, the Danfoss / Eaton Hydrostatic Pump with Integrated Charge Pump is a variable displacement, closed-circuit piston pump built for consistent performance across construction, agriculture, truck and bus, oil and gas, and other mobile applications.
Part of the Eaton Char-Lynn Series 2 platform, this pump supports multiple control options and is Pro-FX ready, making it well-suited for advanced machine control integration. The integrated charge pump simplifies system layout and reduces external component requirements. Proven reliability in high-demand duty cycles is a core characteristic of this series.
SKU: 0004622-185
Supplier Part Number (MPN): 4622-185
Alternate Part Numbers: C1GG61
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part Number4622-185, Alternate Part Number C1GG61, Alternate Part Number MINO-00287X00712
Application
Construction, Agriculture, Truck and Bus, Oil and Gas, and other mobile applications
Brand
Danfoss Power Solutions II (Char-Lynn)
Brand
Char-Lynn
Pack Size
1.00
UOM
EA
Features
Proven reliability in demanding applications|Multiple control options|Pro-FX ready
ICC
Mobile - CC Piston Pumps
Language
English
Net Pack Quantity Units
EA
NMFC
125820
Product Width
8.70
Sub Brand
None
Supplier Part Number
4622-185
Type
Variable Displacement
Product Weight
110.00 lbs
Product Questions & Answers (3)
Question by: Hubert C on Mar 28, 2025, 10:18 AM
How does the internal charge pump in this Danfoss/Eaton hydrostatic pump improve its performance?
Answer by: Customer Support on Mar 30, 2025, 6:26 AM
The internal charge pump in the Danfoss/Eaton hydrostatic pump is a key feature that enhances its overall performance. It helps maintain system pressure and assists in the smooth operation of the pump, especially in heavy-duty applications. This makes it well-suited for demanding environments where consistent performance is critical.
Question by: Clint H on Jul 5, 2025, 1:04 PM
reckon this danfoss eaton pump is meant for closed circuit setups?
Answer by: Customer Support on Jul 6, 2025, 5:06 PM
Yeah, the Danfoss/Eaton Series 2 focuses on heavy duty closed circuit hydrostatic pumping with servo control and an internal charge pump built right in.
Question by: Daryl T on Feb 9, 2026, 9:12 AM
Got a Series 2 heavy duty closed circuit application that needs servo control - will this pump handle that kind of setup?
Answer by: Customer Support on Feb 10, 2026, 1:16 PM
Absolutely, servo control applications are exactly what this pump was built for. The Series 2 heavy duty design gives you the closed circuit operation with integrated charge pump functionality, so you get precise control response along with the reliability needed for demanding servo applications. The built-in charge pump means you won't need separate auxiliary pumping, which simplifies your hydraulic circuit considerably.