Vickers DG4V 3S 2AL M FPBWL

Description & Features

Designed for high-performance applications, the Vickers DG4V 3S 2AL M FPBWL Directional Control Valve is ideal for sectors such as die casting, machine tools, and marine and offshore use. Its robust construction allows it to efficiently manage flow rates up to 80 liters per minute, making it suitable for demanding environments like primary metal production, presses, and turbine control systems. This valve offers versatile configuration options with three- or four-way directional control, ensuring compatibility with various industrial setups.

Easy to mount on industry-standard surfaces, this Vickers valve features Buna-N seals for reliable performance under challenging conditions. It operates at a wattage of 30, providing a balance between power and efficiency. With thousands of models available to meet diverse application needs, the DG4V 3S 2AL M FPBWL exemplifies Vickers' commitment to quality and adaptability in industrial control solutions.

SKU: 02-109650

Supplier Part Number (MPN): 02-109650

Specifications

Brand
Vickers by Danfoss
Actuator Type
Solenoid
Design
60 Series
Dimensions
5.75 in L x 1.8 in W x 3.57 in H
Domestic/Import
Domestic
Electrical Connection
Instaplug Male and Female Receptacle
Indicator Light
With Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Number of Stages
1
Performance
Standard
Seal Material
FKM
Segment Code
B
Series
DG4V-3 60 Series
Spool Position Monitor
Without Spool Position Monitor
Spool Type
Spool 2
Spring Arrangement
Spring Offset End to End LH
Surge Suppressor Damper
Without Surge Suppressor Damper
Valve Mount Type
Subplate/Manifold

Product Questions & Answers (1)

Question by: Roy P on Jan 14, 2026, 1:34 PM
flow rate on this valve is listed at 80 liters per minute -- is that enough for press applications or does it fall short for heavier duty setups?
Answer by: Customer Support on Jan 15, 2026, 8:28 PM
For most press applications, 80 liters per minute is a solid working capacity. Presses are actually listed as one of the intended uses for this valve, so it's not a stretch to put it there. Where you'd want to think twice is if your system is running significantly above that flow ceiling, since 80 LPM is the rated max. Stay within that range and you're in good shape for press work.