VICKERS RV5A 10 S 0 3/

Description & Features

Designed for high-pressure environments, the Vickers RV5A 10 S 0 3/ pressure control valve excels in applications such as harvesters and refuse haulers. With a robust pressure rating of 350 bar (5000 psi) and a flow rate capability of 114 liters per minute, this valve ensures efficient performance even in demanding conditions. Its compact and economical design offers maximum flexibility while minimizing spatial requirements, making it ideal for both mobile and industrial uses.

As part of the renowned Vickers by Danfoss/Eaton series, this spool-style valve exemplifies reliability and high-quality engineering. Its construction supports a flow rate of up to 300 L/min (80 USgpm), enhancing its versatility across various hydraulic systems. With a lead time of 60 days, it promises timely integration into your projects, ensuring operational efficiency and durability.

SKU: 02-112852

Supplier Part Number (MPN): 02-112852

Specifications

Brand
Vickers by Danfoss
Actuator Type
Pilot Operated
Dimensions
4.38 in L x 1 in W x 1 in H
Domestic/Import
Import
Installation Type
Screw-In Cartridge
Nominal Size
10
Number of Ports/Ways
2-Port
Seal Material
Buna-N
Segment Code
B
Series
RV5A-10 Series
Style
Spool

Product Questions & Answers (3)

Question by: Cindy R on Oct 6, 2025, 10:42 AM
Got a RV5-10 already in my harvester that's shot, this the right replacement, or is the A suffix gonna cause me a fitment headache?
Answer by: Customer Support on Oct 8, 2025, 6:30 AM
The RV5A 10 S 0 3/ sits in the Vickers RV5-10 series, so if your existing valve is from that same family, you're looking at a direct replacement candidate. It's a spool-style valve rated to 350 bar (5000 psi) and handles up to 300 L/min, which covers the pressure and flow demands that come with harvester hydraulics. Just keep in mind the lead time on this one runs 60 days, so plan accordingly if downtime is a concern.
Question by: Glen S on Jul 27, 2025, 7:27 AM
How much hydraulic flow can this valve handle without issues?
Answer by: Customer Support on Jul 28, 2025, 12:52 PM
This Vickers RV5A-10 series valve can handle a flow rate up to 114 liters per minute, which translates to roughly 300 liters per minute at its peak. It's designed to give you efficient performance even when you're pushing it hard.
Question by: Eddie C on Jun 2, 2025, 3:35 PM
running a harvester setup, is this RV5A valve meant for that kind of work or is it more of a shop machine thing
Answer by: Customer Support on Jun 4, 2025, 6:23 AM
For real-world mobile equipment, it fits right in. The RV5-10 series valve is called out for harvesters and refuse haulers, and it is also used in both mobile and industrial hydraulic applications.