VICKERS SV3 10V 0 0 115AG

Description & Features

Designed for demanding mobile and industrial environments, the Vickers SV3 10V 0 0 115AG is a 2-way, 2-position normally open solenoid valve rated for pressures up to 350 bar (5,000 psi) and flow rates up to 227 L/min (60 USgpm). This unit operates on 115V AC and carries a nominal flow rate of 45 litres per minute in this configuration.

Built from hardened and ground steel, the valve delivers consistent performance across a range of applications including harvesters, refuse haulers, and general mobile and industrial hydraulic systems. Its compact form factor makes it well suited to installations where space is a consideration without compromising on pressure or flow capability.

Part of the Vickers by Eaton SV3-10 series, this solenoid valve combines reliability with an economical build, making it a practical choice for both OEM and service replacement use.

SKU: 02-113063

Supplier Part Number (MPN): 02-113063

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X02107
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 227 L/min (60 USgpm)|Reliable, economical and compact|Hardened and ground steel
Flow Rate1
45 litre per minute
ICC
SICV Solenoid Valves
Language
English
Product Width
1.53
Special Features
None
Style
2-Way 2-Position Normally Open
Sub Brand
Vickers
Supplier Part Number
02-113063
Voltage
115 volt
Product Weight
0.87 lbs

Product Questions & Answers (3)

Question by: Shane R on Jun 3, 2025, 10:41 AM
got a 115v ac coil on my machine already. is this SV3 valve the right voltage, and what kind of valve is it?
Answer by: Customer Support on Jun 4, 2025, 9:55 PM
Runs on 115 volt AC and it’s a 2 way, 2 position normally open solenoid valve in the Vickers SV3-10 series.
Question by: Janet C on Jun 25, 2025, 4:23 PM
Running a refuse hauler and need to replace a worn-out solenoid valve. This SV3 10V rated for the pressures we're dealing with on that rig?
Answer by: Customer Support on Jun 27, 2025, 1:46 PM
For refuse hauler applications, 350 bar (5,000 psi) is the pressure ceiling on this valve, and it can move up to 227 litres per minute. That combination covers the typical demands on that kind of equipment. The nominal flow for this specific configuration is 45 litres per minute, so if your system runs closer to that range you're in good shape. It's built from hardened and ground steel, which holds up well in the kind of rough-duty mobile environments refuse trucks operate in.
Question by: Kirk M on Jun 23, 2025, 11:43 AM
Will this valve work okay on a refuse truck, seems like a tough environment?
Answer by: Customer Support on Jun 24, 2025, 4:12 PM
With its hardened steel construction, this valve is designed to handle demanding mobile applications like refuse haulers.