VICKERS 35VQTBS25A 2297CC20R

Description & Features

Designed for high-pressure, high-speed hydraulic circuits, the Vickers 35VQTBS25A 2297CC20R is a cast iron vane pump from the 35VQ series, built to deliver consistent volumetric efficiency across demanding industrial cycles. With a flow rate of approximately 176 litres per minute, it is well suited to applications including metal cutting machinery, plastic injection molding equipment, dump trucks, and wheel loaders, as well as oil and gas service equipment.

Buna-N seals provide reliable fluid compatibility in standard hydraulic oil environments. The 35VQ series design supports longer service intervals compared to general-purpose alternatives, making it a practical choice where pump reliability and output consistency are priorities. This pump carries the Vickers brand under the Danfoss/Eaton product family.

SKU: 02-125553-3

Supplier Part Number (MPN): 02-125553-3

Alternate Part Numbers: 35VQTBS25A2297CC20R

Specifications

Brand
Vickers by Danfoss
Cartridge Type
20 Design
Dimensions
7.28 in W x 5.5 in H
Drive Shaft Type
Splined
Housing Material
Iron
Maximum Operating Pressure
2500 psi
Mounting Type
Flanged
Rotation Direction
Clockwise
Seal Material
Buna-N
Series
35VT Series
Vane Type
Fixed Displacement and Balanced

Similar Products

Model Number Rotation Direction Price Action
VICKERS 35VQTBS25A 2297AA20R

02-125553-1

Clockwise

Vickers 35VQTBS25A 2297BA 20L

02-125553-K

Counterclockwise

Vickers 35VQTBS25A 2297CA 20R

02-125553-N

Clockwise

Product Questions & Answers (2)

Question by: Ross T on Aug 3, 2025, 8:19 AM
Got an older Vickers valve that's on its last legs, is the DG4V-3-2A-M-U-H7-60 gonna swap right in without issues?
Answer by: Customer Support on Aug 6, 2025, 10:42 AM
If your system’s voltage and flow specs match, this DG4V-3-2A-M-U-H7-60 valve should swap in seamlessly since it conforms to the DG4V-3 series standard footprint and connections, with 24V DC and up to 80 l/min capacity.
Question by: Harold R on Feb 9, 2026, 7:22 PM
Wondering about installing one of these, any special tricks for mounting it in a tight spot on my rig
Answer by: Customer Support on Feb 11, 2026, 9:22 AM
Installation should follow CETOP 3 standards, which involve affixing it with four screws; make sure the solenoid has clearance and everything's properly aligned to prevent leaks.