VICKERS 35VQTBS25A 2297CC20R

Description & Features

Designed for high-pressure, high-speed hydraulic circuits, the Vickers 35VQTBS25A 2297CC20R is a cast iron vane pump from the 35VQ series, built to deliver consistent volumetric efficiency across demanding industrial cycles. With a flow rate of approximately 176 litres per minute, it is well suited to applications including metal cutting machinery, plastic injection molding equipment, dump trucks, and wheel loaders, as well as oil and gas service equipment.

Buna-N seals provide reliable fluid compatibility in standard hydraulic oil environments. The 35VQ series design supports longer service intervals compared to general-purpose alternatives, making it a practical choice where pump reliability and output consistency are priorities. This pump carries the Vickers brand under the Danfoss/Eaton product family.

SKU: 02-125553-3

Supplier Part Number (MPN): 02-125553-3

Alternate Part Numbers: 35VQTBS25A2297CC20R

Specifications

Alternate Part Numbers
Alternate Part Number 35VQTBS25A2297CC20R, Alternate Part Number MINO-00900X40903
Application
Oil and Gas, Metal Cutting, Dump Truck, Wheel Loader, Plastic Injection Molding
Brand
DANFOSS POWER SOLUTIONS II LLC (VICKERS)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Longer operating life|Oustanding volumetric efficiency|Built for high-pressure, high-speed applications
Flow Rate1
176.05350144 litre per minute
ICC
Hydraulic - Vane Pumps
Language
English
Product Material
Cast Iron
Product Width
8.38
Seal Material
Buna-N
Series
35VQ
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-125553-3
Product Weight
50.00 lbs

Product Questions & Answers (2)

Question by: Ross T on Aug 3, 2025, 8:19 AM
Got an older Vickers valve that's on its last legs, is the DG4V-3-2A-M-U-H7-60 gonna swap right in without issues?
Answer by: Customer Support on Aug 6, 2025, 10:42 AM
If your system’s voltage and flow specs match, this DG4V-3-2A-M-U-H7-60 valve should swap in seamlessly since it conforms to the DG4V-3 series standard footprint and connections, with 24V DC and up to 80 l/min capacity.
Question by: Harold R on Feb 9, 2026, 7:22 PM
Wondering about installing one of these, any special tricks for mounting it in a tight spot on my rig
Answer by: Customer Support on Feb 11, 2026, 9:22 AM
Installation should follow CETOP 3 standards, which involve affixing it with four screws; make sure the solenoid has clearance and everything's properly aligned to prevent leaks.