Vickers CG5 100A CV M FTWL

Description & Features

This Vickers CG5 100A CV M FTWL pressure control valve is designed for applications requiring adjustable pressure relief or regulation, limiting the pressure in a hydraulic circuit to a desired maximum. Its plug-and-play design ensures ease of installation.

This Vickers pressure valve offers high-performance features and moisture resistance, ensuring reliable performance in demanding environments. It has a maximum flow rate of 454 liters per minute. It uses Buna-N seals to maintain a reliable barrier.

SKU: 02-127446

Supplier Part Number (MPN): 02-127446

Specifications

Actuator Type
Pilot Operated, Solenoid
Body Material
Iron
Design
100 Series
Dimensions
5.75 in L x 3.38 in W x 10.09 in H
Domestic/Import
Domestic
Nominal Size
10
Number of Stages
2
Seal Material
Buna-N
Segment Code
B
Series
CG5-10 Series
Valve Mount Type
Subplate
Voltage Rating
110 V at 50 Hz, 115/120 V at 60 Hz

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Brett B on Aug 18, 2025, 6:57 PM
flow rate on this valve is listed at 454 liters per minute -- is that enough for most standard hydraulic relief setups or is it more on the high end?
Answer by: Customer Support on Aug 20, 2025, 11:02 AM
For a pressure control valve, 454 liters per minute puts it well above what most standard industrial hydraulic circuits actually demand. That kind of capacity is more in line with larger equipment or systems where you've got high-volume flow happening continuously. If your circuit runs well below that ceiling, the valve will handle it fine. It's built to limit pressure to whatever maximum you dial in, so the flow rating just tells you it won't become the bottleneck in high-demand applications.
Question by: Diane T on Apr 9, 2025, 7:18 PM
need a valve that’ll keep my hydraulic pressure from getting too high. is this one meant for that?
Answer by: Customer Support on Apr 11, 2025, 7:00 AM
For circuits where you need adjustable pressure relief or regulation, this valve is built to limit hydraulic pressure to a set maximum so the system does not climb past what you want.

Tell us what you need and we'll get back to you.

Fields marked * are required.