Vickers CS5 060A C M FPA5WL

Description & Features

Designed for hydraulic circuits requiring precise pressure management, the Vickers CS5 060A C M FPA5WL is a pressure control valve built to limit system pressure to a defined maximum. It functions as an adjustable pressure relief or regulating valve, making it well-suited for applications where consistent pressure control is critical to circuit integrity.

This valve supports a flow rate of 227 litres per minute and features Buna-N seals for reliable fluid compatibility across common hydraulic media. The plug-and-play design simplifies installation, while moisture-resistant construction supports use in demanding industrial environments. Manufactured under the Vickers brand by Danfoss/Eaton, it falls within the CS5-06 series of pressure valves.

SKU: 02-127725

Supplier Part Number (MPN): 02-127725

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X41244
Application
Applications requiring an adjustable pressure relief or regulating valve to limit the pressure in a hydraulic circuit to a desired maximum
Brand
DANFOSS POWER SOLUTIONS II LLC (VICKERS)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Plug-and-play design|High-performance features|Moisture resistant
Flow Rate1
227 litre per minute
ICC
IV Pressure Valves
Language
English
Product Width
3.28
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-127725
Product Weight
19.00 lbs

Product Questions & Answers (1)

Question by: Lynn W on Feb 15, 2026, 4:33 PM
flow rate on this one is listed at 227 litres per minute -- is that enough for most mid-size hydraulic circuits or is this more of a heavy-duty unit?
Answer by: Customer Support on Feb 17, 2026, 7:00 AM
For a lot of mid-size industrial hydraulic setups, 227 litres per minute sits right in a solid working range. That kind of flow capacity gives you enough headroom for circuits that see variable demand without constantly pushing the valve to its limits. It leans more toward the capable end of the spectrum rather than being a light-duty component, so if your system runs moderate to higher flow requirements, this valve should handle it without being undersized.