Vickers CG5 100A B M FTWL

Description & Features

Designed for applications requiring precise pressure control, the Vickers CG5 100A B M FTWL is an adjustable pressure relief and regulating valve that ensures optimal pressure levels within hydraulic circuits. This plug-and-play valve offers high-performance features and is crafted with moisture-resistant materials to enhance durability and reliability under various environmental conditions. With a substantial flow rate of 454 liters per minute, this valve is suitable for demanding industrial settings.

Constructed with durable Buna-N seal material, the Vickers CG5 100A B M FTWL is part of the renowned Vickers brand, guaranteeing quality and performance. Its compact design, with a width of 3.38 inches, allows for easy integration into existing systems, ensuring seamless operation without the need for extensive modifications. This valve excels in applications where maintaining a desired maximum pressure is critical.

SKU: 02-127861

Supplier Part Number (MPN): 02-127861

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900H00628
Application
Applications requiring an adjustable pressure relief or regulating valve to limit the pressure in a hydraulic circuit to a desired maximum
Brand
DANFOSS POWER SOLUTIONS II LLC (VICKERS)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Plug-and-play design|High-performance features|Moisture resistant
Flow Rate1
454 litre per minute
ICC
IV Pressure Valves
Language
English
Product Width
3.38
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-127861
Product Weight
24.50 lbs

Product Questions & Answers (3)

Question by: Hubert H on Nov 4, 2025, 2:37 PM
Flow rate on this thing is listed at 454 liters per minute, that enough to handle heavy industrial hydraulic circuits without the valve becoming a bottleneck?
Answer by: Customer Support on Nov 6, 2025, 6:47 AM
For most demanding industrial setups, 454 liters per minute is a solid capacity. Pressure relief and regulating valves like this one are sized to keep up with high-flow circuits, and that flow rate puts it well into heavy-duty territory. As long as your system's peak demand stays within that ceiling, you shouldn't run into restriction issues at the valve.
Question by: Kent W on Mar 10, 2026, 5:31 PM
need an adjustable relief valve to keep my circuit from spiking, is this CG5 meant for that kind of job
Answer by: Customer Support on Mar 11, 2026, 7:16 PM
For controlling maximum pressure in a hydraulic circuit, the CG5 100A B M FTWL is built as an adjustable pressure relief and regulating valve. It is used in applications where you need to limit system pressure to a set maximum and hold it there consistently.
Question by: Tommy C on Sep 7, 2025, 9:00 AM
Will this here Vickers valve work alright in a hydraulic system that needs to keep the pressure steady?
Answer by: Customer Support on Sep 8, 2025, 9:49 PM
This Vickers CG5 valve is designed specifically for applications where maintaining a consistent maximum pressure in a hydraulic circuit is critical.