Designed for applications requiring precise pressure regulation, the Vickers CG5 100A B M U B5 is an adjustable pressure relief valve ideal for maintaining desired pressure levels in hydraulic circuits. Featuring a robust plug-and-play design, this valve offers high-performance capabilities and moisture resistance, ensuring reliability in demanding industrial environments. With a flow rate of up to 454 liters per minute, it efficiently manages pressure without compromising performance.

Constructed with Buna-N seals, the valve provides excellent durability and compatibility with various hydraulic fluids. The compact profile, with a width of 3.38 inches, allows for easy integration into existing systems. As part of the trusted Vickers brand, this pressure control valve is a reliable choice for industrial applications requiring consistent pressure management.

SKU: 02-135865

Supplier Part Number (MPN): 02-135865

Specifications

Actuator Type
Pilot Operated, Solenoid
Adjustment Type
Screw with Locknut
Body Material
Iron
Design
100 Series
Dimensions
5.75 in L x 3.38 in W x 10.09 in H
Domestic/Import
Domestic
Hi-Vent Spring
Without Hi-Vent Spring
Indicator Light
Without Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Nominal Size
10
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Series
CG5-10 Series
Spring Arrangement
Spring Offset
Valve Mount Type
Subplate/Manifold
Voltage Rating
110 VAC at 50 Hz, 120 VAC at 60 Hz

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Howard C on Jan 1, 2026, 2:42 PM
flow rate on this thing goes up to 454 liters per minute, is that enough to handle a high-demand hydraulic circuit without it bogging down on pressure control?
Answer by: Customer Support on Jan 3, 2026, 11:06 AM
For most high-volume hydraulic circuits, 454 liters per minute is a solid ceiling. The CG5 100A B M U B5 is built to manage pressure at that flow level without sacrificing control accuracy, so if your system runs below that threshold, you should have plenty of headroom to maintain a stable pressure limit. The valve is adjustable, meaning you can dial in the maximum pressure to match what your circuit actually needs rather than running it at a fixed setting.
Question by: Troy M on Mar 10, 2026, 12:15 PM
If I'm trying to swap out an old valve, what's the width on this one? Gotta make sure it fits in the space I got.
Answer by: Customer Support on Mar 12, 2026, 6:11 AM
The width on this Vickers CG5 valve is 3.38 inches.