VICKERS 2520V17A11-1CC22R

Description & Features

A cast iron dual-stage vane pump designed for demanding industrial applications, the Vickers 2520V17A11-1CC22R belongs to the Vickers VHO Series and delivers a flow rate of approximately 121.2 litres per minute. Its intra-vane cartridge design contributes to reduced operating noise and strong volumetric efficiency across varying load conditions.

Fitted with Buna-N seals, this pump is well-suited for use with standard hydraulic oils in applications such as metal cutting machinery, plastic injection molding equipment, dump trucks, and wheel loaders. The dual-section configuration makes it a practical choice where multiple flow circuits are required from a single pump drive.

SKU: 02-137193-3

Supplier Part Number (MPN): 02-137193-3

Specifications

Brand
Vickers by Danfoss
Cartridge Type
22 Design
Dimensions
308.864 mm L x 174.752 mm W x 146.05 mm H
Displacement
3.4 cu-in Shaft, 2.2 cu-in Cover
Drive Shaft Type
Square Keyed
Flow Rate
17 gpm Shaft, 11 gpm Cover
Housing Material
Iron
Maximum Operating Pressure
2500 psi
Mounting Type
Flanged
Outlet Type
Threaded
Port Connection
Inlet: 4 Bolt Flanged, Outlet 1: 4 Bolt Flanged, Outlet 2: 4 Bolt Flanged
Rotation Direction
Clockwise
Seal Material
Buna-N
Seal Type
Standard
Series
2520V Series
Vane Type
Fixed Displacement and Balanced

Product Questions & Answers (3)

Question by: Neal C on Jul 16, 2025, 12:03 PM
got a machine that needs two hydraulic circuits, is this one of them dual section pumps or am i lookin at the wrong thing
Answer by: Customer Support on Jul 18, 2025, 6:47 AM
For running two flow circuits off one drive, this is a dual stage, dual section VHO Series vane pump, so it is built for that kind of setup.
Question by: Wes B on Jul 28, 2025, 8:34 PM
pump's got dual sections on it, does that mean it can run two separate hydraulic circuits off one shaft, or is the extra section just for higher flow on a single line?
Answer by: Customer Support on Jul 30, 2025, 9:10 AM
Running two separate circuits off one drive is exactly what the dual-section setup is built for. Each section delivers its own flow, so you can feed independent circuits without needing a second pump or a separate drive source. That makes it a solid fit for equipment where you've got multiple functions pulling from one power unit at the same time.
Question by: Kurt T on Jul 25, 2025, 6:53 PM
Can this pump handle the hydraulic oil we typically use in our metal cutting machines?
Answer by: Customer Support on Jul 27, 2025, 2:55 PM
Buna-N seals make this Vickers vane pump well-suited for standard hydraulic oils commonly used in metal cutting and plastic injection molding applications.

Tell us what you need and we'll get back to you.