VICKERS 3520V30A8-1CC22R

Description & Features

Designed for demanding industrial hydraulic circuits, the Vickers 3520V30A8-1CC22R is a double vane pump in the V Series, built on an innovative intra-vane cartridge design that supports low noise output and strong volumetric efficiency. The cast iron housing provides structural durability across high-cycle applications, while Buna-N seals offer reliable fluid compatibility with standard hydraulic oils.

With a flow rate of approximately 121 litres per minute, this pump is well suited for metal cutting machinery, plastic injection molding equipment, dump trucks, and wheel loader systems. The VHO series configuration supports demanding duty cycles where consistent flow delivery is critical.

Commonly identified under alternate part number 3520V30A81CC22R, this unit is sourced from Vickers by Danfoss/Eaton, a widely recognized name in industrial hydraulic components.

SKU: 02-137254-3

Supplier Part Number (MPN): 02-137254-3

Alternate Part Numbers: 3520V30A81CC22R

Specifications

Brand
Vickers by Danfoss
Cartridge Type
22 Design
Dimensions
378.46 mm L x 265.176 mm W x 213.36 mm H
Displacement
5.9 cu-in Shaft, 1.7 cu-in Cover
Drive Shaft Type
Square Keyed
Flow Rate
30 gpm Shaft, 8 gpm Cover
Housing Material
Iron
Maximum Operating Pressure
2500 psi
Mounting Type
Flanged
Outlet Post From CVR End
Outlet 1: Inline with Inlet, Outlet 2: 45 deg CW From Inlet
Outlet Size
3/4 in, 1-1/4 in
Outlet Type
Threaded
Port Connection
Inlet: 4 Bolt Flanged, Outlet 1: 4 Bolt Flanged, Outlet 2: 4 Bolt Flanged
Rotation Direction
Clockwise
Seal Material
Buna-N
Seal Type
Standard
Series
3520 Series
Vane Type
Fixed Displacement and Balanced

Product Questions & Answers (2)

Question by: Pete R on Feb 15, 2026, 8:07 PM
What kind of applications does this pump work well in?
Answer by: Customer Support on Feb 17, 2026, 7:57 AM
This Vickers vane pump is well-suited for applications like metal cutting machinery, plastic injection molding, dump trucks, and wheel loader systems.
Question by: Kirk H on Nov 2, 2025, 6:41 AM
Running a wheel loader that's been chewing through pumps lately. This Vickers a double vane setup or just a single unit?
Answer by: Customer Support on Nov 3, 2025, 4:58 PM
Double vane pump, built on Vickers' intra-vane cartridge design. That configuration generally holds up better under the kind of repetitive load cycles wheel loaders put out, and the cast iron housing adds to its durability in high-cycle applications. Flow rate comes in at just over 121 litres per minute, so it's sized for real work, not light duty.