VICKERS 4525V60A17 86AA22R

Description & Features

Engineered for demanding industrial applications, the Vickers 4525V60A17 86AA22R vane pump offers exceptional performance in oil and gas, metal cutting, dump trucks, wheel loaders, and plastic injection molding. Featuring an innovative intra-vane cartridge design, this pump minimizes noise while maintaining excellent volumetric efficiency. Constructed from durable cast iron, it is built to withstand rigorous conditions and deliver reliable service.

With a flow rate of 121.23 liters per minute, the Vickers 4525V60A17 86AA22R is equipped with Buna-N seals, ensuring superior fluid compatibility and leak resistance. Its compact size, with a width of 10.44 inches, allows for easy integration into existing systems. As part of the renowned VHO series, this pump exemplifies Vickers' commitment to quality and innovation.

SKU: 02-137444-1

Supplier Part Number (MPN): 02-137444-1

Specifications

Brand
Vickers by Danfoss
Cartridge Type
22 Design
Dimensions
15.93 in L x 10.44 in W x 8.5 in H
Displacement
11.8 cu-in Shaft, 3.4 cu-in Cover
Drive Shaft Type
Square Keyed
Flow Rate
60 gpm Shaft, 17 gpm Cover
Housing Material
Iron
Maximum Operating Pressure
2500 psi
Mounting Type
Flanged
Outlet Post From CVR End
Outlet 1: Opposite Inlet, Outlet 2: 135 deg CCW From Inlet
Outlet Size
1 in, 1-1/2 in
Outlet Type
Threaded
Port Connection
Inlet: 4 Bolt Flanged, Outlet 1: 4 Bolt Flanged, Outlet 2: 4 Bolt Flanged
Rotation Direction
Clockwise
Seal Material
Buna-N
Seal Type
Standard
Series
4525 Series
Vane Type
Fixed Displacement and Balanced

Product Questions & Answers (1)

Question by: Wes H on Apr 17, 2025, 2:22 PM
flow rate on this one says 121 liters a minute -- is that for both pump sections combined or just the bigger one?
Answer by: Customer Support on Apr 19, 2025, 11:55 AM
That 121.23 liters per minute figure reflects the combined output of both sections together. The 4525V is a double vane pump, so the two displacement sections work in tandem to hit that total flow. If you're sizing a circuit around this pump, plan for that as your full system delivery number, not a per-section figure.