Vickers DG4V 3 6C M U HL7

Description & Features

Designed for three- or four-way directional control in demanding hydraulic circuits, the Vickers DG4V 3 6C M U HL7 is a single-stage directional control valve rated for flow up to 80 litres per minute. The valve draws on a 18-watt solenoid and uses Buna-N seals, making it well-suited for a range of industrial fluid media and operating environments.

Mounting follows industry-standard subplate patterns, which simplifies integration into new or existing hydraulic systems. Suitable applications span die casting and foundry equipment, machine tools, presses, primary metal and paper processing machinery, marine and offshore installations, test and simulation equipment, and turbine control systems, including wind, steam, and water turbine configurations. The broad application range reflects the extensive model variety available within the DG4V-3 series.

SKU: 02-139025

Supplier Part Number (MPN): 02-139025

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900H72531
Application
Die casting & foundry, Machine tool, Marine/Offshore, Press, Primary metal, paper, Test equipment & simulation, Turbine control (wind, steam, water)
Brand
Danfoss (Power Solutions II LLC)
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
Three- or four-way directional control|Easily mountable on industry-standard surfaces|Thousands of models to suit all applications
Flow Rate1
80 litre per minute
ICC
IV Directional Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1.80
Seal Material
Buna-N
Special Features
None
Sub Brand
Vickers
Supplier Part Number
02-139025
Wattage
18
Product Weight
4.80 lbs

Product Questions & Answers (1)

Question by: Norm E on Feb 9, 2026, 2:42 PM
Flow rating on this one says 80 litres per minute, that hold up for press machinery or is that more of an ideal number?
Answer by: Customer Support on Feb 11, 2026, 6:00 AM
For press applications, 80 litres per minute is a working figure you can plan around. The DG4V-3 series is listed specifically for press use, so the rating is relevant to that kind of duty, not just a lab number. Keep in mind that real-world flow will depend on your system pressure, line sizing, and how the valve is plumbed into the subplate, but 80 LPM is the rated ceiling for this valve.