Vickers CG5 060A C M FW N5

Description & Features

The Vickers CG5 060A C M FW N5 is a pressure control valve designed for applications requiring adjustable pressure relief. It can also serve as a regulating valve to limit pressure in a hydraulic circuit to the desired maximum.

This Vickers valve features a plug-and-play design and is moisture resistant. It has a flow rate of 227 liters per minute and uses Buna-N seals. It measures 2.81 inches in width.

SKU: 02-145351

Supplier Part Number (MPN): 02-145351

Specifications

Actuator Type
Pilot Operated, Solenoid
Adjustment Type
Screw with Locknut
Body Material
Iron
Design
100 Series
Dimensions
6.16 in L x 2.81 in W x 9.65 in H
Domestic/Import
Domestic
Electrical Connection
1/2 in NPT Housing Flying Leads
Hi-Vent Spring
Without Hi-Vent Spring
Indicator Light
Without Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Nominal Size
#06
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Series
CG5-06 Series
Spring Arrangement
Spring Offset
Valve Mount Type
Subplate/Manifold
Voltage Rating
24 VAC at 50/60 Hz

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Shane H on Oct 17, 2025, 7:02 AM
Reckon this valve can handle runnin' pretty much non-stop in a hydraulic system?
Answer by: Customer Support on Oct 18, 2025, 4:35 PM
Designed for applications needing adjustable pressure relief, it can also serve as a regulating valve to limit pressure in a hydraulic circuit to the desired maximum. This suggests it can handle demanding duty cycles, but keep in mind the specific application and required pressure levels.
Question by: Melvin L on Nov 5, 2025, 9:13 PM
does this valve handle 227 liters a minute or is that the max before you start running into trouble
Answer by: Customer Support on Nov 7, 2025, 7:19 AM
That flow rate of 227 liters per minute is the rated capacity for this valve. Running your system at or below that figure keeps things operating within the intended range. Push past it consistently and you'd be working outside what the valve was built for.

Tell us what you need and we'll get back to you.

Fields marked * are required.