VICKERS DG4V32AHMU1B660EN38

Description & Features

The Vickers DG4V32AHMU1B660EN38 is a directional control valve suited for applications such as die casting and foundry work, machine tools, marine and offshore environments, presses, primary metal processing, paper production, test equipment and simulation, and turbine control for wind, steam, and water systems.

This valve features a Buna-N seal material and a flow rate of 80 liters per minute. A special, low-leakage design with high head loss is incorporated, providing typical leakage of 5ml/min/land at 100bar head loss x 2 standard valve. Special spools have increased overlap, installation drawing number 508190, and assembly drawing number 698501.

SKU: 02-146785

Supplier Part Number (MPN): 02-146785

Specifications

Brand
Vickers by Danfoss
Actuator Type
Solenoid
Design
60 Series
Dimensions
5.75 in L x 1.8 in W x 3.42 in H
Domestic/Import
Domestic
Electrical Connection
ISO 4400 Fitted Plugs
Indicator Light
Without Indicator Light
Manual Override
Waterproof
Media
Petroleum Oil
Number of Stages
1
Performance
High
Seal Material
FKM
Series
DG4V-3 60 Series
Special Features
Low Leakage
Spool Position Monitor
Without Spool Position Monitor
Spool Type
Spool 2
Spring Arrangement
Spring Offset End to End
Surge Suppressor Damper
Without Surge Suppressor Damper
Valve Mount Type
Subplate/Manifold

Product Questions & Answers (2)

Question by: Lance W on May 14, 2025, 7:09 AM
Would this valve hold up okay in a marine environment, like on a boat or near the coast?
Answer by: Customer Support on May 15, 2025, 11:06 AM
This Vickers valve is applicable in marine and offshore environments, as well as in die casting, machine tool, primary metal, paper production, and turbine control applications.
Question by: Jean T on Mar 25, 2026, 9:23 AM
what's the leakage spec on this valve? trying to figure out if it'll hold tight enough for a press application we got running pretty much all day
Answer by: Customer Support on Mar 27, 2026, 6:12 AM
Leakage on this valve runs about 5ml per minute per land at 100 bar head loss, which works out to roughly twice that of a standard valve in the same series. The low-leakage design uses special spools with increased overlap to keep things tight. For press work, that tradeoff between leakage control and higher head loss is worth keeping in mind when you're sizing the system.