Vickers CG5 060A FV M FW B5

Description & Features

Designed for hydraulic circuits that require reliable pressure limiting, this adjustable pressure relief and regulating valve delivers consistent performance across demanding industrial applications. The Vickers CG5 060A FV M FW B5 supports flow rates up to 227 litres per minute and features Buna-N seals suited to a wide range of hydraulic fluids.

Built on a plug-and-play design, the valve simplifies installation and replacement within existing hydraulic systems. Moisture-resistant construction supports use in environments where exposure to humidity or condensation is a concern. As part of the Vickers CG5-06 series from Vickers by Danfoss/Eaton, this valve is classified within the pressure valve category and is suited to circuit protection and pressure regulation tasks where a defined maximum pressure must be maintained.

SKU: 02-148875

Supplier Part Number (MPN): 02-148875

Specifications

Actuator Type
Pilot Operated, Solenoid
Adjustment Type
Screw with Locknut
Body Material
Iron
Design
100 Series
Dimensions
5.75 in L x 2.81 in W x 9.65 in H
Domestic/Import
Domestic
Electrical Connection
1/2 in NPT Housing Flying Leads
Hi-Vent Spring
With Hi-Vent Spring
Indicator Light
Without Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Nominal Size
#06
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Series
CG5-06 Series
Spring Arrangement
Spring Offset
Valve Mount Type
Subplate/Manifold
Voltage Rating
110 VAC at 50 Hz, 120 VAC at 60 Hz

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Danny T on Sep 18, 2025, 9:55 AM
Flow rate on this thing goes up to 227 LPM, that enough for most standard industrial setups, or is this valve really meant for lighter duty circuits?
Answer by: Customer Support on Sep 20, 2025, 6:48 AM
For the majority of industrial hydraulic circuits, 227 litres per minute is a solid working capacity. That puts it well within range for mid-to-heavy duty applications where you need reliable pressure limiting without oversizing your valve. It's built for adjustable pressure relief and regulation, so if your circuit needs a defined maximum pressure held consistently under load, this one's sized to handle it without being pushed to its limits in typical setups.