VICKERS FCV7 10 K 0 20

Description & Features

The VICKERS FCV7 10 K 0 20 is a flow control valve designed for demanding mobile and industrial applications, including use in harvesters and refuse haulers. This flow restrictor offers a balance of pressure and flow performance.

This Vickers flow control valve has a maximum flow rate of 45 liters per minute and is rated to 350 bar (5000 psi) and 350 L/min (92 USgpm). Its compact design provides reliable and economical flow control.

SKU: 02-153237

Supplier Part Number (MPN): 02-153237

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00569H78689
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
45 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1.50
Style
Flow Restrictor
Sub Brand
Vickers
Supplier Part Number
02-153237
Product Weight
0.25 lbs

Product Questions & Answers (2)

Question by: Lynn W on Jul 18, 2025, 8:05 PM
What kind of applications does this flow control valve work with?
Answer by: Customer Support on Jul 20, 2025, 8:50 AM
This Vickers flow control valve is applicable for use in harvesters, refuse haulers, along with mobile and industrial applications.
Question by: Kirk S on Jun 9, 2025, 2:08 PM
flow rate on this thing says 45 liters per minute but the pressure rating is listed way higher at 350 bar. how does that work exactly, are those two separate specs?
Answer by: Customer Support on Jun 11, 2025, 6:08 AM
Good catch on that. The 45 liters per minute is the maximum flow rate this valve will pass through the control orifice itself. The 350 bar and 350 L/min ratings reflect the overall pressure and flow capacity of the valve body, meaning the hardware can handle those conditions even though the controlled output is set to 45 LPM. Think of it like a pressure vessel rated well above its working load. You get a valve that won't be stressed at normal operating conditions, which tends to mean longer service life in hard-working equipment.