Vickers DG5S4 022C X 1 T M

Description & Features

The Vickers DG5S4 022C X 1 T M directional control valve is suitable for applications such as die casting and foundry work, machine tools, marine and offshore systems, presses, primary metal processing, the paper industry, test equipment and simulation, and turbine control for wind, steam, and water power. It offers three- or four-way directional control and is easily mountable on industry-standard surfaces. This Vickers valve is designed to suit a wide range of applications.

Featuring a Buna-N seal material and a flow rate of 115 liters per minute, this valve offers reliable performance in demanding industrial environments. Its robust design and adaptability make it a versatile choice for various hydraulic systems.

SKU: 02-155395

Supplier Part Number (MPN): 02-155395

Specifications

Brand
Vickers by Danfoss
Actuator Type
Solenoid, Pilot Operated
Design
30 Series
Dimensions
7.87 in L x 2.63 in W x 6.32 in H
Domestic/Import
Domestic
Electrical Connection
1/2 in NPT Housing Flying Leads
Energy Time
X to Fast Response
Ext Pilot Pressure
Internal
Indicator Light
Without Indicator Light
Int Pilot Drain
Internal
Manual Override
Plain
Media
Petroleum Oil
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Segment Code
C
Series
DG5S4-02 30 Series
Spool Control
Stroke Adjustment Both Ends
Spool Position Monitor
Without Spool Position Monitor
Spool Type
Spool 2
Spring Arrangement
Spring Centered
Surge Suppressor Damper
Without Surge Suppressor Damper
Valve Mount Type
Subplate/Manifold

Product Questions & Answers (2)

Question by: Neal A on May 21, 2025, 8:00 PM
If I'm using this in a die casting setup, what kind of flow rate am I looking at?
Answer by: Customer Support on May 23, 2025, 7:10 AM
This valve is rated for a flow rate of 115 liters per minute, which should be suitable for many die casting and foundry applications.
Question by: Travis F on Jul 29, 2025, 2:15 PM
flow rate on this valve is listed at 115 liters per minute -- is that enough to run a decent-sized press application without choking out?
Answer by: Customer Support on Jul 31, 2025, 7:49 AM
For press applications, 115 liters per minute is a solid flow capacity and falls well within the range those systems typically demand. The DG5S4 022C X 1 T M is actually listed with press use as one of its intended applications, so the flow rating lines up with what that duty requires. As long as your system is sized around that flow ceiling, you shouldn't run into restriction issues under normal press operating conditions.

Tell us what you need and we'll get back to you.