VICKERS RV3 10V S 0 36/

Description & Features

Designed for demanding mobile and industrial environments, the Vickers RV3 10V S 0 36/ is a poppet-style pressure control valve rated for up to 350 bar (5,000 psi) and capable of handling flow rates to 300 L/min (80 USgpm). Its compact form factor is well suited to space-constrained installations where reliable pressure regulation is a priority.

With a rated flow of 76 litres per minute, this valve fits a range of applications including harvesters, refuse haulers, and general mobile hydraulic circuits. The poppet construction supports consistent, economical performance across variable duty cycles typical of mobile equipment. Vickers, a Danfoss/Eaton sub-brand, is a recognized name in pressure control valve design for both mobile and stationary hydraulic systems.

SKU: 02-164301

Supplier Part Number (MPN): 02-164301

Specifications

Brand
Vickers by Danfoss
Actuator Type
Direct Acting
Dimensions
4.38 in L x 1 in W x 1 in H
Domestic/Import
Import
Nominal Size
10
Number of Ports/Ways
2-Port
Seal Material
FKM
Segment Code
B
Series
RV3-10 Series
Style
Poppet

Product Questions & Answers (2)

Question by: Judy C on Nov 23, 2025, 9:13 AM
Will this work alright on a silage chopper?
Answer by: Customer Support on Nov 24, 2025, 1:12 PM
Designed for demanding mobile environments like harvesters, this Vickers RV3 valve is rated to 350 bar (5,000 psi) and can handle flows up to 300 L/min (80 USgpm), so it should be suitable for your application.
Question by: Diane W on Jun 1, 2025, 9:42 AM
Got a refuse hauler that keeps blowing off at inconsistent pressures. Would the RV3-10V hold up to that kind of stop-and-go duty cycle, or is this valve more suited to steady-state industrial work?
Answer by: Customer Support on Jun 3, 2025, 6:01 AM
Poppet-style valves handle variable duty cycles pretty well, and that's actually one of the reasons the RV3-10V gets used in mobile equipment like refuse haulers. The poppet construction gives you consistent pressure response even when flow conditions are changing constantly, which is exactly what you're dealing with on a truck that's cycling through a route all day. Rated up to 350 bar and 300 L/min, it's got enough headroom for most refuse circuit demands, and the 76 L/min rated flow sits in a practical range for that type of application.