VICKERS RV10 10 C 0 2/3283

Description & Features

Designed for mobile and industrial hydraulic circuits, this poppet-style pressure control valve handles flow rates up to 38 litres per minute and is built to the performance standards of the Vickers RV10-10 series. The poppet construction contributes to reliable, consistent pressure regulation across a wide range of duty cycles, making it well suited to demanding applications such as harvesters and refuse haulers.

The VICKERS RV10 10 C 0 2/3283 belongs to a valve family rated to 350 bar (5,000 psi) with capacity up to 300 L/min (80 USgpm) across the series, offering a compact footprint that supports flexible circuit design where space is limited. Manufactured under the Vickers brand within the Danfoss / Eaton portfolio, it falls within the SICV pressure control valve classification.

SKU: 02-164515

Supplier Part Number (MPN): 02-164515

Specifications

Brand
Vickers by Danfoss
Actuator Type
Direct Acting
Dimensions
3.05 in L x 1.5 in W x 1.5 in H
Nominal Size
10
Number of Ports/Ways
2-Port
Seal Material
Buna-N
Series
RV10-10 Series
Style
Poppet

Product Questions & Answers (1)

Question by: Brenda E on Aug 28, 2025, 10:13 AM
Got a RV10-10 series valve on a refuse hauler that's worn out, this the right replacement if my circuit's only pulling around 35 litres per minute?
Answer by: Customer Support on Aug 30, 2025, 6:54 AM
For a refuse hauler running at 35 L/min, this valve fits well within its rated capacity of 38 L/min. The RV10-10 series is actually called out for that kind of application, so you're not forcing it outside its intended use. Poppet-style construction holds up well to the repeated pressure cycles that come with that type of equipment, so it should serve as a solid drop-in for a worn unit in the same series.

Tell us what you need and we'll get back to you.

Fields marked * are required.