VICKERS RV1-10-S-8T-30/

Description & Features

Designed for demanding mobile and industrial applications, the Vickers RV1-10-S-8T-30/ Pressure Control Valve excels in performance and reliability. With a robust pressure rating of 350 bar (5000 psi) and a flow rate of 30 liters per minute, this valve is an ideal choice for harvesters, refuse haulers, and other heavy-duty machinery. Its compact, economical design ensures maximum flexibility while minimizing space requirements, making it a versatile component in hydraulic systems.

This poppet-style valve is equipped with a 1/2" port size, ensuring compatibility with a wide range of industrial setups. As part of the renowned Vickers by Danfoss/Eaton RV1-10 Series, it is engineered for reliability and efficiency, maintaining optimal control under high-pressure conditions. Trust in the proven performance of Vickers' engineering to meet the demands of your hydraulic applications.

SKU: 02-164538

Supplier Part Number (MPN): 02-164538

Specifications

Brand
Vickers by Danfoss
Actuator Type
Direct Acting
Adjustment Type
Screw
Body Material
Steel
Cavity
C-10-2
Connection Type
SAE
Dimensions
2.5 in L x 2 in W x 5.8 in H
Domestic/Import
Import
End Type
SAE
Housing
With Housing
Installation Type
Screw-In Cartridge
Nominal Size
10
Number of Ports/Ways
2-Port
Port Type
SAE
Seal Material
Buna-N
Series
RV1-10 Series
Style
Poppet

Product Questions & Answers (1)

Sign In Hover me Please sign in to submit a question
Question by: Bobby C on Aug 22, 2025, 8:15 PM
got a refuse hauler that's been running a relief valve into the ground, this RV1-10-S-8T-30/ rated to handle that kind of continuous high-pressure work at 350 bar?
Answer by: Customer Support on Aug 24, 2025, 6:55 AM
At 350 bar (5000 psi), this valve is built for exactly that kind of application. Refuse haulers are listed right in the intended use for this series, so it fits the bill on paper. The poppet-style construction holds up well under repeated pressure cycling, which is typical in that type of equipment. The 30 liter per minute flow rate is what it's spec'd for on this particular model, so just make sure that lines up with what your system demands before you commit.