VICKERS RV3-10-S-8T-18/15

Description & Features

Designed for use in demanding environments, the Vickers RV3-10-S-8T-18/15 Pressure Control Valve is an ideal choice for harvesters, refuse haulers, and various mobile and industrial applications. It boasts a robust pressure rating of up to 350 bar (5000 psi) and supports a maximum flow rate of 76 liters per minute, ensuring reliable performance under high-pressure conditions. The valve's compact and economical design provides maximum flexibility while minimizing space requirements, making it a practical addition to your hydraulic systems.

Featuring a 1/2" port size and poppet style, this valve is engineered for efficiency and effectiveness in flow control. The Vickers brand, renowned for its quality and durability, further assures long-term performance and reliability in critical applications. Whether in agricultural machinery or industrial equipment, this valve delivers consistent and dependable pressure control.

SKU: 02-164948

Supplier Part Number (MPN): 02-164948

Specifications

Brand
Vickers by Danfoss
Actuator Type
Direct Acting
Body Material
Aluminum
Connection Type
SAE
Dimensions
2.5 in L x 1.14 in W x 5.8 in H
End Type
SAE
Nominal Size
10
Number of Ports/Ways
2-Port
Seal Material
Buna-N
Series
RV3-10 Series
Style
Poppet

Product Questions & Answers (2)

Question by: Randy C on Sep 26, 2025, 11:35 AM
Running a refuse hauler and need a pressure control valve that won't fold under continuous heavy use. This RV3-10 rated for 5000 psi, or is that a peak number?
Answer by: Customer Support on Sep 28, 2025, 6:32 AM
350 bar, which works out to 5000 psi, is the full pressure rating on this valve. For refuse hauler duty, that's a solid ceiling to work within. The RV3-10 series is specifically called out for mobile applications like that, so it's not a number that applies only to light-duty or intermittent conditions.
Question by: Lance B on Sep 26, 2025, 8:40 AM
Reckon this valve will work on my harvester? It's an older model but the pressure is about right.
Answer by: Customer Support on Sep 27, 2025, 4:41 PM
This valve is designed for use in harvesters, refuse haulers, and other mobile and industrial applications, so it should be suitable if the pressure and flow requirements match your system. Just make sure your system doesn't exceed the 350 bar (5000 psi) pressure rating or the 76 liters per minute flow rate.