VICKERS RV1 10 S 8H 18/

Description & Features

Designed for mobile and industrial hydraulic circuits, the Vickers RV1 10 S 8H 18/ is a poppet-style pressure control valve built to handle demanding environments including harvesters and refuse haulers. The poppet construction provides reliable, repeatable pressure regulation in a compact envelope suited to space-constrained installations.

Rated to 350 bar (5,000 psi) with a maximum flow capacity of 300 L/min (80 USgpm), the RV1-10 series offers substantial pressure handling capability within a physically small package. This unit is configured with a 1/2" port size and a flow rate of 30 litres per minute, making it appropriate for mid-range flow circuits. The design emphasizes flexibility across a broad range of mobile and stationary applications without requiring extensive mounting infrastructure.

SKU: 02-164957

Supplier Part Number (MPN): 02-164957

Specifications

Actuator Type
Direct Acting
Adjustment Type
Screw
Body Material
Steel
Cavity
C-10-2
Connection Type
SAE
Dimensions
2.5 in L x 2 in W x 5.8 in H
Domestic/Import
Import
End Type
SAE
Housing
With Housing
Installation Type
Screw-In Cartridge
Nominal Size
10
Number of Ports/Ways
2-Port
Port Type
SAE
Seal Material
Buna-N
Series
RV1-10 Series
Style
Poppet

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Rick A on Feb 17, 2026, 10:54 AM
Reckon this valve could hold up in a rig running steady all day long?
Answer by: Customer Support on Feb 18, 2026, 8:13 PM
Rated to 350 bar (5,000 psi) with a flow capacity of 300 L/min (80 USgpm), the RV1-10 series is built for demanding environments, including continuous-use applications.
Question by: Keith H on Jun 7, 2025, 8:45 AM
what's the max pressure this valve can hold? got a circuit running pretty hard and need something that ain't gonna give out on me
Answer by: Customer Support on Jun 9, 2025, 7:42 AM
Rated to 350 bar, which works out to 5,000 psi. For a hard-running circuit, that's a solid ceiling. The poppet-style construction keeps pressure regulation consistent and repeatable, so you're not dealing with pressure creep or erratic relief behavior under load. The overall flow capacity tops out at 300 L/min (80 USgpm), though this specific unit is configured for 30 litres per minute, so make sure that flow rate lines up with what your circuit actually needs.