VICKERS PFR2 16-S-0-/12.00

Description & Features

Designed for demanding mobile and industrial applications, the Vickers PFR2 16-S-0-/12.00 is an adjustable, pressure-compensated flow regulator built to maintain consistent flow regardless of load-induced pressure fluctuations. Rated to 350 bar (5,000 psi) with a flow capacity of up to 350 L/min (92 USgpm), it is well-suited for harvesters, refuse haulers, and a broad range of hydraulic systems where precise flow regulation is required.

Part of the Vickers PFR2-16 series, this valve delivers a reliable balance of pressure and flow in a compact, economical package. The adjustable pressure-compensation mechanism allows operators to set and maintain target flow rates across varying operating conditions, making it a practical choice for both mobile equipment and stationary industrial installations.

SKU: 02-165650

Supplier Part Number (MPN): 02-165650

Specifications

Brand
Vickers by Danfoss
Actuator Type
Pressure Compensated
Adjustment Type
Screw
Body Material
Aluminum
Cavity
C-16-3S
Dimensions
7.09 in L x 1.5 in W x 1.5 in H
Domestic/Import
Import
Housing
Without Housing
Mounting Type
Screw-In
Nominal Size
#16
Number of Ports/Ways
3-Port
Port Type
Cartridge
Seal Material
Buna-N
Series
PFR2-16 Series
Spool Seal
Without Spool Seal
Style
Adjustable Pressure Compensated, Flow Regulator

Product Questions & Answers (2)

Question by: Shane P on Jul 15, 2025, 3:37 PM
Got a refuse hauler running some real punishing cycles and need a flow regulator that won't drift on me when the load pressure starts bouncing around. This PFR2 16-S-0-/12.00 hold its set rate pretty steady under those conditions?
Answer by: Customer Support on Jul 17, 2025, 11:55 AM
Pressure-compensated design is exactly what handles that kind of situation. The PFR2-16 maintains consistent flow regardless of load-induced pressure fluctuations, so when your hauler's system pressure starts jumping around, the valve works to hold the target flow rate you've dialed in. It's rated to 350 bar (5,000 psi) and handles up to 350 L/min, which gives it plenty of headroom for demanding mobile duty like refuse equipment.
Question by: Lee M on Apr 26, 2025, 7:39 PM
reckon this would be alright on a silage harvester?
Answer by: Customer Support on Apr 28, 2025, 6:51 PM
Given its suitability for harvesters, this PFR2-16 flow control valve should do the job well. Its pressure-compensated design helps maintain consistent flow, even when the load changes.