VICKERS RV2-10-C-0-20/9.5

Description & Features

Designed for demanding mobile and industrial environments, the VICKERS RV2-10-C-0-20/9.5 is a poppet-style pressure control valve rated to 350 bar (5,000 psi) with a maximum flow capacity of 300 L/min (80 USgpm). Its compact construction suits space-constrained installations where reliable pressure management is required without sacrificing flexibility.

Suited for harvesters, refuse haulers, and a broad range of mobile and industrial hydraulic circuits, this valve delivers consistent performance at a flow rate of 114 litres per minute in typical service conditions. The poppet design supports responsive, repeatable pressure control and contributes to the valve's economical, low-maintenance profile across varied duty cycles.

SKU: 02-168980

Supplier Part Number (MPN): 02-168980

Specifications

Brand
Vickers by Danfoss
Actuator Type
Pilot Operated
Adjustment Type
Cap
Cavity
C-10-2
Dimensions
4.38 in L x 1 in W x 1 in H
Domestic/Import
Import
Housing
Without Housing
Installation Type
Screw-In Cartridge
Nominal Size
10
Number of Ports/Ways
2-Port
Port Type
Cartridge
Seal Material
Buna-N
Series
RV2-10 Series
Style
Poppet

Product Questions & Answers (2)

Question by: Floyd K on Mar 29, 2026, 2:11 PM
How much hydraulic fluid can this valve handle, like what's the max it can take?
Answer by: Customer Support on Mar 30, 2026, 4:57 PM
This pressure control valve can handle a maximum flow of 300 liters per minute, which is about 80 US gallons per minute.
Question by: Hugh L on Sep 9, 2025, 6:33 PM
Got a harvester that's been giving us fits with pressure spikes. Would this RV2-10 handle that kind of duty, or is it more of a light-use valve?
Answer by: Customer Support on Sep 11, 2025, 6:21 PM
Harvesters are actually one of the named applications for this valve, so it's not out of its element there at all. Rated to 350 bar (5,000 psi) with a max flow capacity of 300 L/min, it's built to handle the demands of mobile equipment running hard in the field. The poppet design gives you responsive, repeatable pressure control, which is exactly what you want when you're dealing with pressure spikes rather than steady-state conditions. Typical service flow runs around 114 litres per minute, so as long as your circuit falls within those parameters, this should be a solid fit for that application.