VICKERS FR2 10V S 0 /1.70

Description & Features

Designed for demanding environments, the Vickers FR2 10V S 0 /1.70 is a robust flow control valve ideal for applications such as harvesters, refuse haulers, and various mobile and industrial settings. This adjustable, pressure-compensated flow regulator ensures precise flow control with a maximum flow rate of 38 liters per minute. Built with a perfect balance of pressure and flow, it operates at a pressure of up to 350 bar (5000 psi) and a flow capacity of 350 L/min (92 USgpm), making it both reliable and economical.

As part of the Vickers FR2-10 Series, this valve stands out for its compact design, which facilitates easy integration into diverse systems. Its construction emphasizes durability and performance, adhering to stringent industrial standards. Widely recognized for its efficiency and reliability, the Vickers FR2 10V S 0 /1.70 is a preferred choice for professionals seeking dependable hydraulic solutions.

SKU: 02-169289

Supplier Part Number (MPN): 02-169289

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X08435
Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-169289
Product Weight
0.48 lbs

Product Questions & Answers (2)

Question by: Debbie G on Mar 19, 2026, 7:19 AM
Reckon this would be a good fit for my harvester, or is it more for industrial stuff?
Answer by: Customer Support on Mar 21, 2026, 8:36 AM
Use-case-first: It's well-suited for harvesters, refuse haulers, and a variety of mobile and industrial applications.
Question by: Kurt F on Jan 6, 2026, 11:56 AM
Running a refuse hauler and trying to figure out if this valve'll hold up at full system pressure without bleedin' off flow. What's it rated for?
Answer by: Customer Support on Jan 8, 2026, 6:23 AM
Rated to handle up to 350 bar, which works out to 5000 psi, so it's built to take serious system pressure without issue. Flow capacity tops out at 350 liters per minute, though the regulated output through this valve is set at 38 liters per minute. For refuse hauler work, that kind of pressure rating gives you a solid margin even under heavy demand cycles.