VICKERS FR2 10 F 0 /0.26

Description & Features

Designed for mobile and industrial hydraulic circuits, the Vickers FR2 10 F 0 /0.26 is an adjustable, pressure-compensated flow regulator from the FR2-10 series by Vickers, a Danfoss/Eaton brand. It delivers consistent flow regulation at up to 350 bar (5,000 psi) and supports system flow rates up to 350 L/min (92 USgpm), with a rated flow output of 38 litres per minute for this configuration.

The pressure-compensated design maintains steady output flow regardless of load-induced pressure fluctuations, making it well suited for harvesters, refuse haulers, and a range of mobile and industrial equipment. Its compact form factor supports installation in space-constrained hydraulic assemblies without sacrificing performance or reliability.

SKU: 02-169297

Supplier Part Number (MPN): 02-169297

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X08440
Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-169297
Product Weight
0.48 lbs

Product Questions & Answers (1)

Question by: Denise F on Aug 22, 2025, 6:04 AM
got a refuse hauler that needs steady flow even when the load pressure bounces around pretty good, will a pressure-compensated regulator actually hold the output consistent through all that?
Answer by: Customer Support on Aug 23, 2025, 2:32 PM
Pressure compensation is exactly what handles that situation. The FR2 10 F 0 /0.26 maintains a steady output flow regardless of load-induced pressure swings, so what's happening downstream doesn't pull the flow rate around. Rated output on this unit is 38 litres per minute, and it's built to operate up to 350 bar and 350 L/min system flow. For a refuse hauler dealing with variable load pressure, that compensating design is going to keep your actuator speeds consistent rather than hunting around every time the load shifts.