VICKERS FR1 16 F 0 /0.50

Description & Features

Designed for mobile and industrial hydraulic circuits, the Vickers FR1 16 F 0 /0.50 is a fixed pressure compensated flow regulator built to maintain consistent flow regardless of load-induced pressure variations. Rated to 350 bar (5,000 psi) with a maximum flow capacity of 350 L/min (92 USgpm), it delivers reliable flow control across demanding duty cycles typical of harvesters, refuse haulers, and a broad range of mobile and industrial equipment.

With a working flow rate of 114 litres per minute and a compact, economical form factor, this Vickers by Danfoss/Eaton FR1-16 series valve suits applications where space and budget constraints matter without compromising pressure or flow performance. The fixed pressure compensation style simplifies circuit design where variable adjustment is not required.

SKU: 02-169306

Supplier Part Number (MPN): 02-169306

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X08446
Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
114 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1.50
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-169306
Product Weight
0.72 lbs

Product Questions & Answers (1)

Question by: Tammy Y on Feb 15, 2026, 5:04 PM
Got a harvester that's been giving us fits with inconsistent flow whenever the load shifts around. Would a fixed pressure compensated valve like this one keep things steady, or do I need something adjustable?
Answer by: Customer Support on Feb 17, 2026, 6:36 AM
Fixed pressure compensation is exactly what handles that kind of problem. The FR1 16 keeps flow consistent even as load-induced pressure variations change throughout the work cycle, so what you're sending downstream stays predictable regardless of what the machine is doing. For a harvester application where you don't need to dial in different flow rates on the fly, the fixed style actually simplifies your circuit and removes one more variable from the equation. Running at a working flow rate of 114 litres per minute with a ceiling of 350 L/min and 350 bar pressure rating, it's got plenty of headroom for demanding harvest cycles.