Designed for demanding mobile and industrial applications, the Vickers FR2 10 S 0 /5.80 is an adjustable, pressure-compensated flow regulator well-suited to harvesters, refuse haulers, and a broad range of industrial hydraulic circuits. The pressure-compensated design maintains consistent flow regardless of load-induced pressure fluctuations, contributing to reliable circuit performance across variable operating conditions.
Rated to 350 bar (5,000 psi) with a system capacity of 350 L/min (92 USgpm), this valve handles high-pressure duty while remaining compact enough for space-constrained installations. At this specific configuration, the controlled flow rate is 38 litres per minute. Part of the Vickers by Eaton FR2-10 series, it balances economical construction with the performance consistency expected in both mobile and fixed industrial hydraulic systems.
SKU: 02-169472
Supplier Part Number (MPN): 02-169472
Loading related products…
Specifications
Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-169472
Product Weight
0.48 lbs
Product Questions & Answers (2)
Question by: Earl M on May 9, 2025, 9:05 PM
If I'm usin' this on a refuse truck, will the flow stay steady even when the pressure spikes?
Answer by: Customer Support on May 11, 2025, 6:46 AM
Designed for demanding mobile applications like refuse haulers, the pressure-compensated design helps maintain a consistent flow rate, even when the pressure fluctuates due to changing loads.
Question by: Joyce G on Dec 1, 2025, 7:38 PM
Running this on a refuse hauler right now and need to know the controlled flow rate before I swap it in. What's it set to on this particular unit?
Answer by: Customer Support on Dec 3, 2025, 6:54 AM
38 litres per minute is the controlled flow rate for this specific configuration. The pressure-compensated design keeps that flow steady even when load pressures shift around, so what you set is what you get under normal operating conditions. Should drop right into a refuse hauler circuit without any surprises on the flow side.