Designed for demanding mobile and industrial applications, the Vickers FR2 10V S 0 /10.00 flow control valve offers a robust solution with its adjustable pressure-compensated flow regulation. This valve is engineered to handle up to 350 bar (5000 psi) and a flow rate of 38 liters per minute, ensuring a perfect balance of pressure and flow.
Its compact and economical design makes it ideal for use in harvesters and refuse haulers. The valve's reliable performance under high-pressure conditions is a testament to the quality associated with the Vickers brand by Danfoss/Eaton. With a maximum flow capacity of 350 liters per minute (92 USgpm), it effortlessly supports various hydraulic systems, providing consistent and controlled fluid management.
SKU: 02-169550
Supplier Part Number (MPN): 02-169550
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X02038
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-169550
Product Weight
0.48 lbs
Product Questions & Answers (1)
Question by: Janice S on Apr 17, 2025, 6:17 AM
what's the max pressure this valve can handle before it starts giving you trouble
Answer by: Customer Support on Apr 18, 2025, 8:49 PM
Rated up to 350 bar, which works out to 5000 psi. That's a solid ceiling for most demanding mobile and industrial setups, so unless you're pushing something well outside that range, it should hold up without issue.