VICKERS FR2 10 K 0 /0.50

Description & Features

Designed for demanding mobile and industrial environments, the Vickers FR2 10 K 0 /0.50 is an adjustable, pressure-compensated flow regulator built to deliver consistent flow control across variable load conditions. With a flow rate of 38 litres per minute and a system pressure capability of up to 350 bar (5,000 psi), this valve is well-suited for use in harvesters, refuse haulers, and a broad range of mobile and stationary hydraulic circuits.

Part of the Eaton Vickers FR2-10 series, this compact valve balances reliable performance with an economical design footprint. The pressure-compensated construction maintains steady output flow regardless of upstream or downstream pressure fluctuations, making it a practical choice where precise flow regulation is a priority. Its adjustable configuration allows for on-system tuning without requiring component replacement.

SKU: 02-169564

Supplier Part Number (MPN): 02-169564

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00569H78763
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-169564
Product Weight
0.48 lbs

Product Questions & Answers (2)

Question by: Lyle T on Jan 18, 2026, 8:03 AM
got a harvester with a flow issue, what kinda valve is this FR2-10 and what’s it do
Answer by: Customer Support on Jan 19, 2026, 9:01 PM
An adjustable, pressure compensated flow regulator like the Vickers FR2-10 is used to control hydraulic flow in a steady way even when system pressure changes, so your actuator speed stays more consistent.
Question by: Kirk G on Dec 26, 2025, 6:49 AM
flow rate on this one says 38 liters per minute but the series overall goes up to 92 gpm, which number actually applies to what i'd be getting?
Answer by: Customer Support on Dec 28, 2025, 6:50 AM
The 38 liters per minute figure is the rated flow for this specific valve, the FR2 10 K 0 /0.50. The 92 USgpm capacity you're seeing reflects the broader FR2-10 series ceiling, not this particular unit. So for sizing and circuit design purposes, plan around 38 L/min for this model.