VICKERS PSV1 10 F 0 2/1

Description & Features

The Vickers PSV1 10 F 0 2/1 is a versatile pressure control valve designed to perform efficiently in various industrial and mobile applications, including harvesters and refuse haulers. Manufactured by Danfoss Hydraulics, this valve is known for its reliability and compact design, ensuring optimal space utilization and flexibility in complex hydraulic systems.

With a maximum pressure rating of 350 bar (5000 psi) and a flow capacity of up to 300 L/min (80 USgpm), the valve meets demanding operational requirements. Its spool style design enhances precision in pressure regulation, making it an ideal choice for environments requiring robust performance without compromising on space.

SKU: 02-170299

Supplier Part Number (MPN): 02-170299

Specifications

Actuator Type
Direct Acting
Adjustment Type
Factory Set
Cavity
C-10-3
Configuration
Normally Closed
Dimensions
3.78 in L x 1 in W x 1 in H
Domestic/Import
Import
Housing
Without Housing
Installation Type
Screw-In Cartridge
Language
English
Number of Ports/Ways
3-Port
Port Type
Cartridge
Seal Material
Buna-N
Series
PSV1-10 Series
Style
Spool

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Jerry E on Aug 19, 2025, 5:24 PM
Reckon this valve'll hold up okay on a refuse hauler? Seems like that'd be a tough application.
Answer by: Customer Support on Aug 20, 2025, 6:06 PM
Designed for demanding industrial and mobile uses, this Vickers pressure control valve is well-suited for refuse haulers, along with other applications like harvesters.
Question by: Kirk J on Nov 12, 2025, 7:05 AM
Running this valve on a refuse hauler that cycles pretty hard throughout the day. Does 300 liters a minute give enough headroom for that kind of demand, or is that pushing it?
Answer by: Customer Support on Nov 13, 2025, 2:24 PM
At 300 L/min (80 USgpm) and rated up to 350 bar (5000 psi), this valve is built with refuse hauler applications specifically in mind. That flow capacity gives you solid working room for the kind of repetitive, high-demand cycles those machines put out. The pressure rating holds up to what mobile hydraulic systems in that duty class typically require, so you're not running right at the edge of its limits under normal operation.