VICKERS DPS2-10-V-S-0-40

Description & Features

The Vickers DPS2-10-V-S-0-40 logic element valve is part of the Vickers by Danfoss / Eaton DPS2-10 Series, suitable for mobile and industrial applications, including use in harvesters and refuse haulers. This spool style valve enhances machine performance, shortens the design process, and minimizes manufacturing costs.

This logic element valve offers a 60 litre per minute flow rate and a pressure rating of 350 bar (5000 psi), ensuring reliable performance in demanding hydraulic circuits.

SKU: 02-171544

Supplier Part Number (MPN): 02-171544

Specifications

Brand
Vickers by Danfoss
Body Material
Aluminum
Configuration
Normally Closed
Dimensions
3-3/4 in L x 1 in W x 1 in H
Domestic/Import
Import
Installation Type
Screw-In Cartridge
Language
English
Number of Ports/Ways
3-Port
Seal Material
FKM
Series
DPS2-10 Series
Style
Spool

Similar Products

Model Number Configuration Pressure Rating Seal Material Price Action
VICKERS DPS2 10 T S 0 40

02-112713

Normally Closed

Buna-N

VICKERS DPS210PF020

02-112750

Normally Closed

Buna-N

VICKERS DPS2-10-V-F-0-20

02-112831

Normally Closed

FKM

VICKERS DPS2 10 P F 0 40

02-112964

Normally Closed

Buna-N

VICKERS DPS2-10-F-F-0-20

02-113158

Normally Open

Buna-N

VICKERS DPS2-10-R-F-0-20

02-113159

Normally Open

Buna-N

VICKERS DPS2 10 T F 0 160

02-151006

Normally Closed

Buna-N

VICKERS DPS2 10 R F 0 40

02-151021

Normally Open

Buna-N

VICKERS DPS2 10 R F 0 160

02-153298

Normally Open

Buna-N

VICKERS DPS2 10V P F 0 160

02-161007

Normally Closed

FKM

VICKERS DPS2 10 S S 0 40

02-161134

Normally Closed

Buna-N

VICKERS DPS2 10V F F 0 80

02-161177

Normally Closed

FKM

VICKERS DPS2 10 S F 0 160

02-161369

Normally Closed

Buna-N

VICKERS DPS2 10 V F 0 160

02-161467

Normally Closed

FKM

VICKERS DPS2-10-T-S-0-160

02-177338

Normally Closed

Buna-N

VICKERS DPS2-10V-F-F-0-160

02-180710

Normally Closed

FKM

Product Questions & Answers (2)

Question by: Hugh C on Mar 9, 2026, 8:09 AM
Will this work okay in a hydraulic setup on a harvester?
Answer by: Customer Support on Mar 11, 2026, 6:19 AM
This Vickers logic element valve is well-suited for mobile and industrial applications, including use in harvesters to enhance machine performance.
Question by: Janet B on Dec 27, 2025, 7:01 PM
flow rate on this one says 60 L/min but the features mention 400 L/min -- which number actually applies to this valve?
Answer by: Customer Support on Dec 29, 2025, 6:24 AM
The 60 litre per minute figure is the rated flow for this specific unit, the DPS2-10-V-S-0-40. The 400 L/min (100 USgpm) referenced in the series features reflects the broader DPS2-10 series capability, not this particular configuration. So for sizing your circuit, 60 L/min is the number you want to work with.

Tell us what you need and we'll get back to you.

Fields marked * are required.