VICKERS PSV2 10 C 0 6/

Description & Features

Ideal for harvesters, refuse haulers, and various mobile and industrial applications, the Vickers by Danfoss / Eaton PSV2-10 Series Pressure Control Valve offers reliable performance in demanding environments. Designed for high efficiency, this spool-style valve operates at a maximum pressure of 350 bar (5000 psi) and a flow rate of 23 liters per minute. Its compact design ensures maximum flexibility while minimizing the space required for installation, making it a cost-effective solution for hydraulic systems.

Built to withstand rigorous conditions, the Vickers PSV2 10 C 0 6/ features a robust construction that ensures long-term durability. The valve's ability to handle a flow capacity of up to 300 L/min (80 USgpm) further enhances its versatility across various applications. With a commitment to quality and performance, this pressure control valve is a dependable choice for any industrial setup requiring precise pressure regulation.

SKU: 02-171692

Supplier Part Number (MPN): 02-171692

Specifications

Brand
Vickers by Danfoss
Actuator Type
Direct Acting
Adjustment Type
Cap
Cavity
C-10-3
Configuration
Normally Closed
Dimensions
5.15 in L x 1 in W x 1 in H
Domestic/Import
Import
Housing
Without Housing
Installation Type
Screw-In Cartridge
Language
English
Number of Ports/Ways
3-Port
Port Type
Cartridge
Seal Material
Buna-N
Series
PSV2-10 Series
Style
Spool

Similar Products

Model Number Pressure Rating Dimensions Price Action
VICKERS PSV2 10 F 0 12/11

02-170240

4.09 in L x 1 in W x 1 in H

VICKERS PSV2 10 S 0 24/15

02-170399

5.15 in L x 1 in W x 1 in H

VICKERS PSV2 10 S 0 24/10

02-170401

5.15 in L x 1 in W x 1 in H

VICKERS PSV2 10 S 0 12/11

02-170683

5.15 in L x 1 in W x 1 in H

VICKERS PSV2 10 S 0 24/20

02-173493

5.15 in L x 1 in W x 1 in H

Product Questions & Answers (2)

Question by: Connie B on Mar 13, 2026, 11:09 AM
How much hydraulic pressure can this valve handle without blowing up?
Answer by: Customer Support on Mar 14, 2026, 11:57 AM
This Vickers PSV2-10 series valve is rated for a maximum pressure of 350 bar, which is about 5000 psi. You don't want to exceed that.
Question by: Lynn P on Jun 4, 2025, 9:10 AM
what kind of machines is this valve built for, like does it work on harvesters and that sort of equipment?
Answer by: Customer Support on Jun 6, 2025, 6:04 AM
Harvesters and refuse haulers are actually the primary applications this valve was built around, along with broader mobile and industrial hydraulic systems. So if you're running that type of equipment, it fits right in with what this valve was designed to handle.