VICKERS NV1-8V-K-0

Description & Features

Rated for flows up to 45 litres per minute, the Vickers NV1-8V-K-0 is a compact flow restrictor valve designed for reliable flow control across mobile and industrial hydraulic circuits. It is well suited to demanding applications including harvesters and refuse haulers, where consistent flow management under varying conditions is essential.

Part of the Vickers NV1-8 Series by Danfoss/Eaton, this valve supports system pressures up to 350 bar (5,000 psi) with series flow capacity reaching 350 L/min (92 USgpm). Its compact footprint makes it a practical choice where space is limited without compromising on pressure or flow performance. The design emphasises reliability and economy, making it appropriate for both mobile equipment and fixed industrial installations.

SKU: 02-176040

Supplier Part Number (MPN): 02-176040

Specifications

Brand
Vickers by Danfoss
Dimensions
2.4 in L x 0.87 in W x 0.87 in H
Domestic/Import
Import
Installation Type
Screw-In Cartridge
Language
English
Nominal Size
#08
Number of Ports/Ways
2-Port
Seal Material
FKM
Series
NV1-8 Series
Style
Flow Restrictor

Product Questions & Answers (2)

Question by: Connie M on Jun 24, 2025, 8:46 PM
What kind of machinery is this flow valve typically found on?
Answer by: Customer Support on Jun 26, 2025, 7:53 PM
It is often used on harvesters and refuse haulers but also fits well into other mobile and industrial hydraulic applications.
Question by: Gene T on Feb 2, 2026, 6:58 PM
Got a harvester that's been running hot and I think the flow control's worn out, what's the max flow this valve handles before it starts struggling?
Answer by: Customer Support on Feb 3, 2026, 9:30 PM
Rated for up to 45 litres per minute on its own port, it holds up well in demanding mobile equipment like harvesters. The broader NV1-8 series it belongs to can handle series flow up to 350 L/min, which is around 92 US gallons per minute, so there's plenty of headroom in a multi-valve circuit. Pressure-wise, the system tops out at 350 bar or 5,000 psi. For a harvester application running hard through a full season, those ratings put it solidly in range for reliable day-to-day flow control.

Tell us what you need and we'll get back to you.