Vickers Pressure COMPENSATED Flow CNTRL

Description & Features

This Vickers Pressure COMPENSATED Flow CNTRL is a fixed pressure compensated flow regulator designed for mobile and industrial applications, including use in harvesters and refuse haulers. This flow control valve offers a reliable, economical, and compact solution where a perfect balance of pressure and flow is required.

This Vickers by Danfoss / Eaton FR5-10 Series flow control valve has a flow rate of 23 liters per minute and a maximum pressure of 350 bar (5000 psi), with a maximum flow of 350 L/min (92 USgpm).

SKU: 02-176466

Supplier Part Number (MPN): 02-176466

Specifications

Brand
Vickers by Danfoss
Actuator Type
Pressure Compensated
Dimensions
2.07 in L x 1 in W x 1 in H
Domestic/Import
Import
Lead Time
40
Mounting Type
Screw-In
Nominal Size
10
Number of Ports/Ways
2-Port
Seal Material
Buna-N
Segment Code
A
Series
FR5-10 Series
Style
Fixed Pressure Compensated, Flow Regulator

Product Questions & Answers (1)

Question by: Hank G on May 13, 2025, 8:41 AM
Got a harvester that's been running hot and losing flow consistency real bad. Would a fixed pressure compensated valve like this one help keep things steady?
Answer by: Customer Support on May 15, 2025, 8:30 AM
Fixed compensation is exactly what handles that kind of problem. When pressure fluctuates upstream or downstream, an uncompensated valve lets flow drift all over the place. This FR5-10 series holds output at a set 23 liters per minute regardless of those pressure swings, so your harvester actuators stay consistent even when load conditions change. Rated to 350 bar, it's got plenty of headroom for the pressure spikes you'd see in that kind of work.

Tell us what you need and we'll get back to you.