VICKERS ERV1-16-8.00-12T-24DG

Description & Features

Designed for versatility in mobile and industrial applications, the Vickers ERV1-16-8.00-12T-24DG proportional valve delivers reliability and efficiency. This compact and economical valve supports rated flows up to 160 L/min (42 USgpm) and is ideal for equipment such as harvesters and refuse haulers. With a 3/4" port size and a spool style, it ensures maximum flexibility while minimizing the space required for installation.

Operating at 24 volts, this valve is part of the Vickers ERV1-16 Series, known for its dependable performance. The flow rate of 132 liters per minute highlights its capability, making it a suitable choice for demanding systems. As a product under the Vickers brand by Danfoss/Eaton, it is crafted to meet the needs of professional environments, ensuring long-lasting service.

SKU: 02-176784

Supplier Part Number (MPN): 02-176784

Specifications

Actuator Type
Electronically Proportionally Controlled
Body Material
Aluminum
Connection Type
SAE
Dimensions
3-1/2 in L x 2-1/2 in W x 6-1/2 in H
End Type
SAE
Nominal Size
#16
Number of Ports/Ways
2-Port
Seal Material
Buna-N
Series
ERV1-16 Series
Style
Spool

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Lee J on Apr 6, 2025, 11:56 AM
Reckon this valve'll hold up good on my harvester?
Answer by: Customer Support on Apr 7, 2025, 6:35 PM
Use-case-first: This valve is well-suited for harvesters and refuse haulers, as that's what it's designed for.
Question by: Randy F on Aug 6, 2025, 9:01 AM
Flow rate on this one says 132 liters per minute but the max is listed at 160 L/min, which number do I actually plan around for my system?
Answer by: Customer Support on Aug 7, 2025, 7:06 PM
Both numbers are real, just measuring different things. The 160 L/min figure is the rated flow ceiling for the valve itself, meaning that's the upper boundary it's built to handle. The 132 liters per minute is the actual flow rate for this specific configuration. When sizing your system, work with the 132 L/min number as your operating reference and treat 160 as the hard limit you don't want to push past.