Designed for mobile and industrial hydraulic circuits, the Vickers FR1-16-F-0-/3.00 is a fixed pressure compensated flow regulator rated for pressures up to 350 bar (5,000 psi) and flow rates up to 350 L/min (92 US gpm). The unit delivers a flow rate of 114 litres per minute, providing consistent, regulated output regardless of load-induced pressure variations.
Built around a compact, economical form factor, this valve suits demanding applications including harvesters and refuse haulers where reliable flow control in tight installation envelopes is a priority. As part of the Vickers FR1-16 series by Danfoss, it balances pressure compensation and flow regulation in a single, straightforward assembly suited to both mobile and stationary hydraulic systems.
SKU: 02-177196
Supplier Part Number (MPN): 02-177196
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X08825
Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
114 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1.50
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-177196
Product Weight
0.72 lbs
Product Questions & Answers (1)
Question by: Ross T on Aug 3, 2025, 8:23 PM
Got a harvester that's been giving us fits with inconsistent flow whenever the load changes. Would something like this valve sort that out?
Answer by: Customer Support on Aug 5, 2025, 6:31 AM
Pressure-compensated flow regulators are built exactly for that situation. The FR1-16-F-0-/3.00 holds a steady output of 114 litres per minute regardless of load-induced pressure swings, so what's downstream gets consistent flow even when working conditions change. It's rated to handle pressures up to 350 bar and flows up to 350 L/min, which puts it well within range for typical harvester hydraulic circuits. The fixed compensation style means there's no adjustment needed once it's in place, which keeps things simple when you're trying to cut down on troubleshooting time.