The Vickers FR5-10-F-0-4.10 is a robust flow control valve designed for demanding environments, including harvesters and refuse haulers, as well as other mobile and industrial applications. This flow regulator is engineered to provide a perfect balance of pressure and flow, achieving up to 350 bar (5000 psi) and a flow rate of 23 liters per minute. Its compact design ensures reliability and cost-effectiveness without compromising on performance.
This fixed pressure compensated valve from Vickers by Danfoss / Eaton is an ideal solution for systems requiring precise flow regulation. With a capacity of handling up to 350 L/min (92 USgpm), it ensures optimal performance under various operational conditions. The Vickers brand is renowned for its quality and durability, making this valve a trusted choice for industrial applications.
SKU: 02-180644
Supplier Part Number (MPN): 02-180644
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X08919
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
23 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Special Features
None
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-180644
Product Weight
0.26 lbs
Product Questions & Answers (2)
Question by: Travis B on Apr 29, 2025, 10:28 AM
Got a harvester that needs a reliable flow regulator and I keep burning through cheaper valves. This a fixed pressure compensated unit or does it float around depending on load?
Answer by: Customer Support on Apr 30, 2025, 6:29 PM
Fixed pressure compensated is exactly what this is. It holds a steady flow rate regardless of pressure changes elsewhere in the circuit, which is why it holds up better in demanding cycles like harvest equipment sees. The valve is rated to 350 bar (5000 psi) and handles up to 350 liters per minute system capacity, with a regulated output of 23 liters per minute. That combination of pressure tolerance and fixed compensation is what keeps it from acting up the way cheaper, uncompensated valves tend to do under variable load conditions.
Question by: Ray P on Mar 23, 2026, 2:32 PM
Can this handle the pressure in my hydraulic system? I'm running around 4800 psi.
Answer by: Customer Support on Mar 25, 2026, 8:44 AM
This Vickers flow control valve can handle pressures up to 5000 psi, so you should be good to go.