RV11-12-S-50/30

Description & Features

Designed for demanding mobile and industrial environments, the RV11-12-S-50/30 is a spool-style pressure control valve from Vickers by Danfoss Power Solutions, suited for use in harvesters, refuse haulers, and a broad range of industrial hydraulic systems. It handles flow rates up to 190 litres per minute and is rated to 350 bar (5,000 psi), making it well-matched to high-pressure circuit protection requirements.

Part of the RV11-12 series, this valve balances a compact form factor with strong performance capability, supporting up to 300 L/min (80 USgpm) across the series. Its design prioritises space efficiency without compromising flexibility, making it a practical choice where installation space is constrained. The spool construction contributes to reliable, consistent pressure regulation across a wide range of mobile and stationary applications.

SKU: 02-180721

Supplier Part Number (MPN): 02-180721

Specifications

Actuator Type
Pilot Operated
Adjustment Type
Screw
Cavity
C-12-2
Dimensions
4.64 in L x 1.25 in W x 1.25 in H
Housing
Without Housing
Installation Type
Screw-In Cartridge
Nominal Size
#12
Number of Ports/Ways
2-Port
Port Type
Cartridge
Seal Material
Buna-N
Series
RV11-12 Series
Style
Spool

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Shawn W on Jan 31, 2026, 7:28 PM
If I'm runnin' this on some heavy equipment, like a harvester, what kinda pressure can it handle?
Answer by: Customer Support on Feb 2, 2026, 6:03 AM
This valve is rated up to 350 bar (5,000 psi), making it a good fit for high-pressure systems commonly found in mobile equipment.
Question by: Kirk J on Jan 31, 2026, 8:11 PM
flow rate on this one goes up to 190 L/min, but I seen the series listed at 300 L/min. which number actually applies to what I'm buying here?
Answer by: Customer Support on Feb 2, 2026, 1:27 PM
The 190 litres per minute figure is the rated flow for this specific valve. The 300 L/min rating you're seeing refers to the broader RV11-12 series ceiling, which covers multiple configurations. For the RV11-12-S-50/30 unit itself, plan around the 190 L/min number when sizing your circuit.