VICKERS FAR1-10-H-A6T

Description & Features

The Vickers FAR1-10-H-A6T offers a reliable solution for managing hydraulic flow in demanding environments such as harvesters and refuse haulers. This robust flow control valve, designed by Eaton Vickers, excels in both mobile and industrial applications. It efficiently balances pressure and flow, operating at up to 350 bar (5000 psi) and supporting a maximum flow rate of 350 L/min (92 USgpm), while the standard flow rate is 38 L/min. Its compact design integrates a pressure-compensated style with free reverse flow, ensuring seamless operation and reduced space requirements.

Featuring a 3/8" port size, the Vickers FAR1-10-H-A6T is engineered to meet stringent performance demands while maintaining economic viability. Its reliable construction ensures lasting durability, making it a preferred choice for industry professionals seeking efficiency and performance in hydraulic systems. With the assurance of Eaton Vickers' renowned quality, this valve is a valuable component for any hydraulic setup.

SKU: 02-182316

Supplier Part Number (MPN): 02-182316

Alternate Part Numbers: FAR1-10-H-A6T

Specifications

Alternate Part Numbers
Alternate Part Number FAR1-10-H-A6T, Alternate Part Number MINO-00900X09027
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Port Size
3/8"
Product Width
1.75
Style
Pressure Compensated with Free Reverse Flow
Sub Brand
Vickers
Supplier Part Number
02-182316
Product Weight
1.42 lbs

Product Questions & Answers (2)

Question by: Brent B on Nov 19, 2025, 8:20 PM
flow rate on this valve says 38 liters per minute but the series spec shows 350 L/min capacity -- which one applies to my setup?
Answer by: Customer Support on Nov 21, 2025, 6:17 PM
The 38 liters per minute is the rated flow for this specific valve configuration. The 350 L/min figure reflects the broader FAR1-10 series ceiling, not what this particular unit is built to handle. If your system demands more than 38 L/min through a single point, you'd be looking at a different valve in the lineup. For most mobile equipment running at moderate flow, 38 L/min is plenty capable.
Question by: Stan E on May 29, 2025, 8:42 AM
got a flow control in mind for a harvester, what kind of valve is this one exactly?
Answer by: Customer Support on May 30, 2025, 4:53 PM
It’s a pressure compensated flow control valve with free reverse flow, so it’s meant to regulate flow in one direction while allowing reverse flow back through without being metered the same way.