Designed for demanding mobile and industrial environments, the Vickers FR2-10V-K-0-/4.00 is an adjustable, pressure-compensated flow regulator valve rated to 350 bar (5,000 psi) with a flow capacity of 350 L/min (92 USgpm). This compact, in-line flow control valve delivers consistent flow regulation across varying load conditions, maintaining reliable performance in high-pressure hydraulic circuits.
With a working flow rate of 38 litres per minute, this valve is well suited for use in harvesters, refuse haulers, and a broad range of mobile and industrial hydraulic applications. The pressure-compensated design ensures stable output regardless of upstream or downstream pressure fluctuations, making it a practical choice where precise flow control is a priority. The compact form factor supports installation in space-constrained installations without sacrificing performance.
SKU: 02-182767
Supplier Part Number (MPN): 02-182767
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00900X09055
Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-182767
Product Weight
0.48 lbs
Product Questions & Answers (1)
Question by: Billy G on May 17, 2025, 8:38 PM
Got a harvester that's been giving us grief with inconsistent flow under varying load conditions. Would this Vickers FR2-10V valve actually hold steady output when pressure fluctuates, or is that just marketing talk?
Answer by: Customer Support on May 19, 2025, 7:29 PM
Pressure-compensated valves like this one are built specifically for that problem. The design actively maintains consistent flow regardless of upstream or downstream pressure changes, so what you're describing is exactly the kind of situation it handles. Running 38 litres per minute at the working flow rate, it holds that output stable even when load conditions shift, which is common in harvester hydraulic circuits. That's the core function, not just a feature listed for show.