Designed for demanding mobile and industrial hydraulic systems, the Vickers FR5-10-F-0-1.00 is a fixed pressure compensated flow regulator rated for up to 350 bar (5,000 psi) and capable of handling flows up to 350 L/min (92 US gpm). This particular configuration is set to a flow rate of 23 litres per minute, making it well-suited for precise flow control in applications where consistent output is critical regardless of load-induced pressure variation.
Part of the Vickers by Danfoss FR5-10 Series, this valve is compact and economically designed for reliable service across a range of equipment including harvesters and refuse haulers, as well as broader mobile and industrial hydraulic circuits. The fixed pressure compensation style ensures stable flow delivery without requiring manual adjustment, simplifying integration into systems where consistent performance is a priority.
SKU: 02-198002
Supplier Part Number (MPN): 02-198002
Loading related products…
Specifications
Alternate Part Numbers
Alternate Part NumberMINO-00569H82499
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
23 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-198002
Product Weight
0.26 lbs
Product Questions & Answers (2)
Question by: Daryl C on Aug 17, 2025, 11:11 AM
If I'm hookin' this up to a harvester, what kinda flow rate am I lookin' at outta this thing?
Answer by: Customer Support on Aug 18, 2025, 9:19 PM
This Vickers FR5-10-F-0-1.00 is set to a fixed flow rate of 23 liters per minute, which makes it ideal for applications where you need a consistent output, no matter how much the pressure changes.
Question by: Lyle W on Jun 29, 2025, 11:09 AM
flow rate on this one is fixed at 23 L/min, right? just want to make sure i aint gotta fiddle with any adjustments after installation
Answer by: Customer Support on Jun 30, 2025, 12:56 PM
Correct, the flow is set at the factory and stays put. No adjustment screws, no calibration needed on your end. Once it's plumbed in, it holds 23 litres per minute regardless of load pressure changes in the circuit. That fixed compensation is kind of the whole point with this style of valve, keeps your output consistent without any ongoing tuning.