VICKERS-SV2-10-4-0-12BW

Description & Features

Designed for demanding mobile and industrial environments, the VICKERS-SV2-10-4-0-12BW is a 4-way, 2-position solenoid valve built to perform in applications such as harvesters and refuse haulers. Operating on a 12-volt DC signal, it delivers reliable directional control with a rated flow of 23 litres per minute and is engineered to handle pressures up to 350 bar (5,000 psi).

Constructed from hardened and ground steel, this Vickers-branded valve offers a compact, economical footprint without sacrificing durability. Its design suits both stationary industrial circuits and mobile hydraulic systems where space and reliability are equally important considerations.

SKU: 02-199017

Supplier Part Number (MPN): 02-199017

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X46672
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 227 L/min (60 USgpm)|Reliable, economical and compact|Hardened and ground steel
Flow Rate1
23 litre per minute
ICC
SICV Solenoid Valves
Language
English
Product Width
1.53
Special Features
None
Style
4-Way 2-Position
Sub Brand
Vickers
Supplier Part Number
02-199017
Voltage
12 volt
Product Weight
0.96 lbs

Product Questions & Answers (2)

Question by: Judy W on Jan 16, 2026, 4:25 PM
Running this on a refuse hauler that's been giving us fits with directional control. What kind of pressure can this valve actually hold up to before it becomes a problem?
Answer by: Customer Support on Jan 18, 2026, 6:55 AM
Built for exactly that kind of heavy use, the SV2-10-4-0-12BW is rated to handle up to 350 bar, which works out to 5,000 psi. That puts it well within range for most refuse hauler hydraulic circuits. The hardened and ground steel construction helps it hold up under the kind of repeated cycling those applications demand.
Question by: Vince H on Jul 10, 2025, 1:49 PM
What kind of applications is this valve best suited for? I'm working on a project that involves both mobile and stationary hydraulic systems.
Answer by: Customer Support on Jul 11, 2025, 9:08 PM
This Vickers valve is designed to handle both mobile and stationary industrial circuits, which makes it a good fit if you're working with both types of hydraulic systems. It's specifically noted for use in applications like harvesters and refuse haulers, which speaks to its durability.