VICKERS CBV2-12V-S-0-A-30/-A

Description & Features

Designed for demanding mobile and industrial environments, the Vickers CBV2-12V-S-0-A-30/-A is a 3-ported, externally piloted motion control valve built to handle challenging load management requirements. It is rated to 350 bar (5,000 psi) and supports flow up to 114 litres per minute, making it well-suited for high-pressure hydraulic circuits where load stability is critical.

Compliant with ISO 8643, this valve delivers consistent performance across a range of applications including harvesters and refuse haulers. The external pilot configuration supports precise control of moving loads, and the CBV2-12 series design reflects the established Vickers engineering standard now carried under the Danfoss/Eaton portfolio.

SKU: 02-199658

Supplier Part Number (MPN): 02-199658

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00569X02435
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 550 L/min (143 USgpm)|Excellent stability for moving loads|ISO8643 Compliant
Flow Rate1
114 litre per minute
ICC
SICV Motion Control Valves
Language
English
Net Pack Quantity Units
EA
Port Size
None
Product Width
1.25
Special Features
None
Style
3-Ported, Externally Piloted
Sub Brand
Vickers
Supplier Part Number
02-199658
Product Weight
0.79 lbs

Product Questions & Answers (1)

Question by: Cindy C on Jun 11, 2025, 11:12 AM
Got a harvester that's been giving us fits with load creep on the header lift circuit. Would this CBV2-12V valve be the right kind of fix for something like that?
Answer by: Customer Support on Jun 13, 2025, 6:20 AM
Load creep on a lift circuit is exactly the kind of problem this valve series is built around. The CBV2-12V is a motion control valve with external pilot operation, meaning it holds a load in place until a deliberate pilot signal tells it to move. At 350 bar (5,000 psi) rated pressure and flow capacity up to 114 litres per minute, it has the headroom to handle the demands of a harvester header circuit without choking flow during operation. The ISO 8643 compliance also means it meets the standard specifically associated with mobile equipment load-holding and motion control applications, so it's not a general-purpose valve being pressed into that role.