VICKERS-PTS9-8N-0000-160-00-A

Description & Features

Designed for demanding mobile and industrial applications, the Vickers PTS9-8N-0000-160-00-A is a directional control valve from the Vickers by Danfoss/Eaton PTS9-8 Series. Rated to 350 bar (5,000 psi) and capable of handling up to 265 L/min (70 USgpm), this valve delivers dependable flow management in high-pressure hydraulic circuits. The nominal flow rate for this configuration is 19 litres per minute.

Compact construction keeps installation space requirements low while maintaining the flexibility needed across a range of system configurations. Typical deployments include harvesters, refuse haulers, and various mobile and industrial hydraulic systems where reliable directional control in a space-efficient package is a priority.

SKU: 02-199935

Supplier Part Number (MPN): 02-199935

Specifications

Actuator Type
Hydraulic, Pilot Operated
Cavity
C-8-5S
Detent Option
Without Detent
Dimensions
4.71 in L x 1.87 in W x 1.87 in H
Domestic/Import
Import
Function
Pilot to Shift Valve
Housing
Without Housing
Installation Type
Screw-In Cartridge
Language
English
Number of Ports/Ways
5-Port, 3-Way
Port Type
Cartridge
Seal Material
Buna-N
Series
PTS9-8 Series
Style
Spool

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Todd K on Jan 14, 2026, 6:27 PM
Got a harvester that's been giving us fits with the directional control setup, and I'm trying to figure out if this valve can handle the pressure we're running. What's the max this thing is rated for?
Answer by: Customer Support on Jan 16, 2026, 8:14 AM
Rated to 350 bar, which works out to 5,000 psi. For most harvester hydraulic circuits, that's well within range. The flow capacity tops out at 265 litres per minute (70 USgpm), so it's built to handle demanding conditions without being a bottleneck in your system.
Question by: Cindy B on Apr 26, 2025, 4:25 PM
Reckon this valve would hold up on a refuse truck, dealin' with all that hydraulic pressure all day?
Answer by: Customer Support on Apr 28, 2025, 11:31 AM
This Vickers directional control valve is rated to 350 bar (5,000 psi) and can handle flows up to 265 L/min (70 USgpm), so it should be well-suited for the demands of a refuse truck hydraulic system.

Tell us what you need and we'll get back to you.