Vickers Screw IN CartRIDGE Valve

Description & Features

Designed for mobile and industrial hydraulic circuits, this Vickers Screw-in Cartridge Valve belongs to the PSV2-8 series of pressure control valves from Vickers by Danfoss/Eaton. The spool-style design supports a flow rate of 132 litres per minute, with a series rating of up to 350 bar (5000 psi) and 300 L/min (80 USgpm), making it well-suited to demanding duty cycles.

Typical applications include harvesters, refuse haulers, and a broad range of mobile and industrial hydraulic systems. The cartridge format provides a compact, space-efficient installation footprint without sacrificing performance or reliability.

SKU: 02-200198

Supplier Part Number (MPN): 02-200198

Specifications

Alternate Part Numbers
Alternate Part Number MINO-00900X03689
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 300 L/min (80 USgpm)|Reliable, economical and compact|Maximum flexibility and minimum space
Flow Rate1
132 litre per minute
ICC
SICV Pressure Control Valves
Language
English
Net Pack Quantity Units
EA
Port Size
None
Product Width
0.87
Style
Spool
Sub Brand
Vickers
Supplier Part Number
02-200198
Product Weight
0.47 lbs

Product Questions & Answers (2)

Question by: Warren D on Aug 3, 2025, 7:13 PM
Flow rate on this one shows 132 litres per minute, but the series rating says 300 L/min. Which number actually applies to what I'm running through it?
Answer by: Customer Support on Aug 4, 2025, 7:16 PM
Both figures are real, just covering different things. The 132 litre per minute figure is the rated flow for this specific cartridge valve. The 300 L/min and 350 bar numbers reflect the broader PSV2-8 series ceiling, meaning the platform itself can handle up to those levels across the full product family. For sizing your circuit, go with the 132 L/min as the working limit for this particular valve.
Question by: Gary W on Feb 26, 2026, 8:59 AM
Reckon this cartridge valve would hold up okay on a refuse hauler? Those things run pretty hard.
Answer by: Customer Support on Feb 27, 2026, 8:54 PM
Designed for demanding duty cycles, this Vickers screw-in cartridge valve is well-suited for applications like refuse haulers, as well as harvesters and other mobile and industrial hydraulic systems. It's rated up to 350 bar (5000 psi) and 300 L/min (80 USgpm).