VICKERS CV1-10-P-0-140

Description & Features

Designed for demanding mobile and industrial applications, the Vickers CV1-10-P-0-140 Check Valve delivers robust performance in harvesters and refuse haulers. This poppet-style valve is engineered for high operational efficiency, supporting a flow rate of up to 45 liters per minute. It operates reliably at pressures up to 350 bar (5000 psi) and features low spring settings, making it ideal for systems requiring precise control and minimal pressure drop. The Vickers branding ensures a commitment to quality and durability, making it a trusted choice for hydraulic systems demanding reliability and performance.

SKU: 02-200754

Supplier Part Number (MPN): 02-200754

Specifications

Actuator Type
Direct Acting
Dimensions
1 in L x 1.86 in W x 1 in H
Language
English
Mounting Type
Screw-In
Nominal Size
10
Number of Ports/Ways
2-Port
Seal Material
Buna-N
Series
CV1-10 Series
Style
Poppet

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Warren H on Jul 29, 2025, 7:05 AM
flow rate on this one says 45 L/min but the features mention 227 L/min, which number actually applies to this valve?
Answer by: Customer Support on Jul 30, 2025, 6:51 PM
The 45 liters per minute figure is the rated flow for this specific CV1-10-P-0-140 configuration. The 227 L/min value reflects the broader CV1-10 series ceiling, not what this particular unit is set up to handle. If your system is running anywhere near that higher number, you'd be looking at a different model in the lineup.
Question by: Terry M on Aug 30, 2025, 6:59 PM
I'm wondering about using this valve in a machine that's running pretty much all the time. Is it made for that kinda duty cycle?
Answer by: Customer Support on Sep 1, 2025, 10:17 AM
Designed for demanding mobile and industrial uses like you'd find in harvesters and refuse haulers, this Vickers check valve should hold up well in a system requiring constant operation.