VICKERS DPS2-12-F-F-0-160VALV

Description & Features

Designed for demanding mobile and industrial hydraulic circuits, the Vickers DPS2-12-F-F-0-160VALV is a spool-style logic element valve from the Vickers by Danfoss/Eaton DPS2-12 Series. Rated to 350 bar (5,000 psi) with a system flow capacity of 400 L/min (100 USgpm), this valve is built to handle high-pressure, high-flow applications where reliable directional control is critical.

With a flow rate of 114 litres per minute and a spool-type configuration, this logic element suits a range of applications including harvesters and refuse haulers, as well as broader mobile and stationary industrial hydraulic systems. The DPS2-12 Series is engineered to simplify circuit design and reduce manufacturing complexity, making it a practical choice for hydraulic system integrators and OEM machine builders working across multiple platform types.

SKU: 02-200793

Supplier Part Number (MPN): 02-200793

Specifications

Brand
Vickers by Danfoss
Body Material
Aluminum
Configuration
Normally Open
Dimensions
3.65 in L x 3.65 in W x 1.4 in H
Domestic/Import
Import
Language
English
Number of Ports/Ways
3-Port
Seal Material
Buna-N
Series
DPS2-12 Series
Style
Spool

Similar Products

Model Number Configuration Seal Material Price Action
VICKERS DPS2-12-V-F-0-080VALV

02-201158

Normally Closed

FKM

VICKERS DPS2-12-P-F-0-080VALV

02-201296

Normally Closed

Buna-N

Product Questions & Answers (2)

Question by: Ricky W on Jan 10, 2026, 6:42 AM
Reckon this valve will hold up on a refuse hauler running near constant?
Answer by: Customer Support on Jan 12, 2026, 6:51 AM
Designed for demanding mobile hydraulic circuits, this Vickers DPS2-12 series valve is rated to 350 bar (5,000 psi) and a system flow capacity of 400 L/min (100 USgpm), making it suitable for high-pressure, high-flow applications like refuse haulers.
Question by: Brenda K on Mar 2, 2026, 1:45 PM
flow rate on this one is listed at 114 litres per minute but the system capacity says 400 L/min -- how does that work exactly?
Answer by: Customer Support on Mar 3, 2026, 5:38 PM
The 400 L/min figure reflects the maximum flow capacity the valve series is rated to handle across the system, while the 114 litre per minute figure is the specific flow rate for this particular valve configuration. Think of it like a pipe rated for a certain pressure range but sized for a specific job. This unit is built for circuits where 114 L/min is the target flow, and it does that at up to 350 bar. The broader series rating just tells you the ceiling the design was engineered around.

Tell us what you need and we'll get back to you.