Vickers CPF3S 12 BFF W 3S M

Description & Features

Designed for hydraulic circuits requiring adjustable pressure control, the Vickers CPF3S 12 BFF W 3S M is a pressure control valve built to limit system pressure to a defined maximum. It functions as either a relief or regulating valve, making it suitable for a broad range of industrial hydraulic applications where precise pressure management is critical.

Rated for flow up to 800 litres per minute and 30 watts, this valve is constructed with Buna-N seals for reliable sealing performance across common hydraulic fluid types. Its plug-and-play design supports straightforward installation, and moisture-resistant construction helps maintain consistent performance in demanding environments. The valve carries the Vickers brand, now part of the Danfoss / Eaton product line.

SKU: 02-305127

Supplier Part Number (MPN): 02-305127

Specifications

Actuator Type
Solenoid
Adjustment Type
Screw with Locknut
Body Material
Iron
Connection Type
SAE
Design
20 Series
Dimensions
7.55 in L x 8.39 in W x 8.92 in H
Domestic/Import
Domestic
Drain
Internal
Gauge Port Thread
1/4 in BSP
Hi-Vent Spring
Without Hi-Vent Spring
Indicator Light
Without Indicator Light
Manual Override
Plain
Media
Petroleum Oil
Number of Stages
2
Performance
Standard
Seal Material
Buna-N
Series
CPF33S-12 Series
Valve Mount Type
Flange-Mounted
Voltage Rating
110 VAC at 50 Hz, 120 VAC at 60 Hz

Product Questions & Answers (2)

Sign In Hover me Please sign in to submit a question
Question by: Ralph M on Jun 17, 2025, 8:02 PM
Reckon this'll hold up okay in a humid environment?
Answer by: Customer Support on Jun 19, 2025, 6:29 AM
Built with moisture-resistant construction, this pressure control valve should maintain consistent performance even in demanding environments.
Question by: Ronnie M on May 12, 2025, 1:47 PM
flow rate on this thing is listed at 800 litres per minute -- is that enough for most industrial press or clamping setups running continuous cycles?
Answer by: Customer Support on May 14, 2025, 6:28 AM
For the majority of industrial press and clamping applications, 800 litres per minute is a solid ceiling. Most mid-range hydraulic circuits in that category run well under that figure during normal operation, so headroom usually isn't a concern. Where it matters more is making sure your system's operating pressure stays within the valve's adjustable range, since this one is built to cap pressure at a set maximum rather than regulate flow volume directly. As long as your circuit needs adjustable pressure relief or regulation, the flow capacity here covers a wide range of industrial work.